Instruction Manual
HI 2151 SERIES WEIGHT CONTROLLERS REMOTE I/O OPTION
4-4
5 = Dipswitch
Settings (interior)
Status Byte
bit 0 Reserved for future use
bit 1 Enables gross weight output on RS232 port once per second
bit 2 Calibration lockout for NTEP (Legal for Trade) mode
bit 3 Ignore incoming serial checksums (RS232 port)
bit 4 Peak force is result of averaged gross weight
bit 5 NTEP (Legal for Trade) mode enable
bit 6 Eliminate “>” on print out (RS232 port)
bit 7 Designates instrument to be in “Blind” configuration
8 = MSB of 24 Bit
Weight Value
bit 0 bit 16 of weight data
bit 1 bit 17 of weight data
bit 2 bit 18 of weight data
bit 3 bit 19 of weight data
bit 4 sign bit 20
bit 5 sign bit 21
bit 6 sign bit 22
bit 7 sign bit 23
9 = Sync Pulse 0-7 This byte increments every 50 milliseconds
(new data available)
Example of Screen
Printout
NOTE: The addresses begin with the letter I not the number I.
ADDRESS 17 0 ADDRESS 17 0
I:000 0000 0000 0000 0000 I:020 0100 0010 0011 1001
I:001 0000 0000 0000 0000 I:021 0000 0110 0000 0110
I:002 0000 0000 0000 0000 I:022 0000 0000 0000 0000
I:003 0000 0000 0000 0000 I:023 0000 0000 0000 0000
I:004 0000 0000 0000 0000 I:024 0000 0000 0000 0000
I:005 0000 0000 0000 0000 I:025 0000 0000 0000 0000
I:006 0000 0000 0000 0000 I:026 0000 0000 0000 0000
I:007 0000 0000 0000 0000 I:027 0000 0000 0000 0000
I:010 0000 0000 0000 0000 I:030 0000 0000 0000 0000
I:011 0000 0000 0000 0000 I:031 0000 0000 0000 0000
I:012 0000 0000 0000 0000 I:032 0000 0000 0000 0000
I:013 0000 0000 0000 0000 I:033 0000 0000 0000 0000
I:014 0000 0000 0000 0000 I:034 0000 0000 0000 0000
I:015 0000 0000 0000 0000 I:035 0000 0000 0000 0000
I:016 0000 0000 0000 0000 I:036 0000 0000 0000 0000
I:017 0000 0000 0000 0000 I:037 0000 0000 0000 0000
CHANGE SPECIFY NEXT PREV FORCE
RADIX ADDRESS FILE FILE MONITOR
F1 F5 F8 F9