Instruction Manual

Chapter 5 - Block Transfers
5-3
Dipswitch Settings (interior) Status
bit 0 Reserved for future use
bit 1 Enables gross weight output on RS232 port once per second
bit 2 Calibration lockout for NTEP (Legal for Trade) mode
bit 3 Ignore incoming serial checksums (RS232 port)
bit 4 Peak force is result of averaged gross weight
bit 5 NTEP (Legal for Trade) mode enable
bit 6 Eliminate “>” on print out (RS232 port)
bit 7 Reserved for blind unit toggle
Remote Function Status
bit 8 Force display to Rate-of-Change mode
bit 9 Add current net weight to total
bit 10 Hold value on display
bit 11 Hold option card updates
bit 12 Force display to Net weight mode
bit 13 Toggle lbs/kg
bit 14 Acquire Tare
bit 15 Print request (RS232 and BCD ports)
Note: When the HI 2151WC is configured as a blind unit, the status of the
dipswitches are not visible. See section on blind operation for more
information.
12
Rate-of-Change
Peak force of weight
Total weight in accumulator
Gross Weight
Net Weight
Tare Value
Note: All weight data is in the units (lbs., kgs.) which were used at the time of
calibration.
2
2
2
2
2
2
3
5
7
9
11
13
TOTAL NUMBER OF WORDS 15
BLOCK READ COMMAND NUMBER 1: Full status and weight data
START
WORD DEFINITIONS: #WORDS WORD
TABLE 5-2: BLOCK READ COMMAND NUMBER 1: FULL STATUS AND WEIGHT DATA