Instruction Manual

Chapter 5 - Block Transfers
5-7
Block Read
Command Number
4: Read Tare Value
TABLE 5-7: BLOCK READ COMMAND NUMBER 4: READ TARE VALUE
Block Read
Command Number
5: Calibration
Parameters
BLOCK READ COMMAND NUMBER 4: Read Tare Value
START
WORD DEFINITIONS: #WORDS WORD
Command number: A value of 4 (decimal)
bit 0 0
bit 1 0
bit 2 1
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
bits 8 - 15 Reserved for future use
10
Tare Value 21
TOTAL NUMBER OF WORDS 3
BLOCK READ COMMAND NUMBER 5:Calibration Parameters
START
WORD DEFINITIONS: #WORDS WORD
Command number: A value of 5 (decimal)
bit 0 1
bit 1 0
bit 2 1
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
bits 8 - 15 Reserved for future use
10
Units of Measure
bits 0 - 7 A value of 0 for pounds, or 1 for kilograms
Decimal point position (places to the right of the decimal)
bits 8 - 15 A value from 0 to 5
11
Totalizer decimal point position (places to the right of the decimal)
bis 0 - 7 A value from 0 to 5
C2™, Second Generation Calibration
bits 8 - 15 Load Cell Count
12
Display Graduation size (‘count by): A value of 1,2,5,10,20,50,100,200, or 500 1 3