TABLE 5-8: BLOCK READ COMMAND NUMBER 5: CALIBRATION PARAMETERS
Block Read
Command Number
6: Configuration of
Rate-of-Change
TABLE 5-9: BLOCK READ COMMAND NUMBER 6: CONFIGURATION OF RATE-OF-CHANGE
Motion Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing
range
14
Zero Tolerance: A sixteen bit value representing the low 16 bits of the 20 bit internal weighing range 1 5
Number of readings averaged: A value from 1 to 200
Note: Number of averages will temporarily read 200 if the instrument was in the CAL menu while
this block read occurred.
16
Span weight value or C2
®
, Second Generation reference point value‘‘
27
Scale Capacity (Full limit of scale): A 20 bit number in proper integer format 2 9
Mid-point Linearity Calibration Value: A 20 bit number in proper integer format 2 11
TOTAL NUMBER OF WORDS 13
BLOCK READ COMMAND NUMBER 5:Calibration Parameters
START
WORD DEFINITIONS: #WORDS WORD
BLOCK READ COMMAND NUMBER 6: Configuration of Rate-of-Change
START
WORD DEFINITIONS: #WORDS WORD
Command number: A value of 6 (decimal)
bit 0 0
bit 1 1
bit 2 1
bit 3 0
bit 4 0
bit 5 0
bit 6 0
bit 7 0
bits 8 - 15 Reserved for future use
10
Displayed Rate-of-Change time units: A value of 0 to 2 (0=sec, 1=min, 2=hr) 1 1
Rate-of-Change timebase evaluation period in seconds
0 = 1 second 4 = 5 seconds 8 = 15 seconds 12 = 240 seconds
1 = 2 seconds 5 = 6 seconds 9 = 30 seconds 13 = 450 seconds
2 = 3 seconds 6 = 10 seconds 10 = 60 seconds 14 = 900 seconds
3 = 4 seconds 7 = 12 seconds 11 = 120 seconds 15 = 1800 seconds
12