Instruction Manual
Chapter 5 - Block Transfers
5-15
Block Write
Command Number
51: Activate Scale
Functions
TABLE 5-16: BLOCK WRITE COMMAND NUMBER 51: ACTIVATE SCALE FUNCTIONS
BLOCK WRITE COMMAND NUMBER 51: Activate Scale Functions
START
WORD DEFINITIONS: #WORDS WORD
Command number: A value of 51 (decimal)
bit 0 1
bit 1 1
bit 2 0
bit 3 0
bit 4 1
bit 5 1
bit 6 0
bit 7 0
Remote Functions Byte
bit 8 Acquire TARE (Set tare value = current gross weight)*
bit 9 Initiates print on standard RS232 or optional BCD port*
bit 10 Add current Net weight to Total*
!
bit 11 Clear Peak Hold register*
!
bit 12 Clear Totalizer Accumulation*
!
bit 13 Zero the instrument*
bit 14 Enable Zero Tracking (Blind Unit Only)
bit 15 Reserved for future use
*Note: The bit must be toggled to activate this function
!Note: Only active if the instrument is ordered with this option
10
TOTAL NUMBER OF WORDS 1