Owner's manual
Chapter 7 - Operation
7-15
Dip Switch #1 (S3)
Position Bit Function ("ON" position)
1 80 Multi-drop
2 01 Calibrate toggle (Non NBS applications)
3 40 Serial command lockout (Requests OK)
4 02 Option menu lockout
5 04 Set point menu lockout
620Spare
7 08 Lb/Kg, N/G, Tare and Zero lockout
8 10 Zero track
SUB-CMD Meaning
Dip Switch #2 (S2)
Position Bit Function ("ON" position)
1 08 Ignore incoming checksums
2 10 On is averaged peak hold, Off is instantaneous
peak hold
320NBS
4 04 NBS Re-Cal toggle switch
540Spare
680Spare
702Spare
801Spare
SUB-CMD Meaning
E Excitation Monitor
ERR
OKK
OFF
3. E IT
®
serial command
Results Description
OKK No Errors Detected
ERR Error Detected
OFF IT is Not Turned On
4. I Load cell input command. Used primarily to
check the analog input section of the unit. The command
will return the number of averaged counts that is currently