Owner's manual

HI 2151/30WC MANUAL
7-16
SUB-CMD Meaning
REM Level status of the Remote Input connector (J2)
pins.
Bit Remote Function Bit Remote Function
01 Rate of change 10 Net
02 Totalizer 20 Lbs/Kgs
04 Display Hold 40 Tare
08 Option Hold 80 Print
5. Q The query command obtains a block of information as
follows:
SUB-CMD Meaning
A. Gross weight (6 bytes plus label)
B. Net weight (6 bytes plus label)
C. Peak gross value reached (6 bytes plus label)
D. Internal counts (6 bytes)
E. Total net accumulation (6 bytes plus label)
F. Rate of change value (6 bytes plus label)
G. Not Used (6 bytes set to 000000)
H. Not Used (6 bytes set to 000000)
I. LED status (4 bytes)
J. Relay status (2 bytes)
Command Meaning
F Format the output data. Used to
configure data to be sent on a
TRANSMIT or PRINT request.
The SUB-CMD letters can be
issued in any combination or
order and are as follows:
SUB-CMD Meaning
GGross
NNet
TTare
RROC
S Set point, Deadband, Preact
NOTE: The last (6th) position is one of the following (must be accompanied by at least one of
the above SUB-CMDs):
- Continuous printing.
P Button on front panel "triggers" output.
NOTE: The default FORMAT is GNTRSP.