Owner's manual
HI 2151/30WC MANUAL
7-18
For example, to set point one to 1000 Lbs gross on instrument number
10, the outgoing command would be as follows:
NOTE: The example uses decimal and mnemonic abbreviation format for clarity, however,
the actual data would be in ASCII format.
Command Meaning
C Allows you to change modes between Net/Gross,
lb/kg, or Hold/Unhold Display.
SUB-CMD Meaning
M Toggles between Net and Gross weight mode.
UUnit (toggles between Lbs. and Kg.)
H Toggles between display hold and unhold.
Command Meaning
A Used to auto tare or auto zero the instrument.
SUB-CMD Meaning
T Auto tare the instrument. (Scale must not be in
motion.)
Z Auto zero the instrument.(Scale must not be in
motion and mode must be set to Gross)
PPrint command. Functionally the same as the print
button on the key board.
The data setup through the format command will be
sent to the port configured as a printer.
Command Meaning
P1 or P2 Print to either ports 1 or 2.
An optional "subcommand" of up to 37 ASCII characters may be
entered and will be printed before the formatted data.
SUB-CMD Meaning
37 ASCII characters maximum.
H The ASCII characters supplied in the subcommand
(maximum of 20 characters) will be printed as a
heading and saved for each subsequent X - transmit
START
CHAR
INSTRUMENT
ADDRESS
CMD
SUB
CMD
CMD
7 BYTE
DATA
D-7 . . . D-1
MODE CR
2 BYTE CHECKSUM
EOT
CHK-1 CHK-2
> 10 S S 1 1000 G CR CHK-1 CHK-2 EOT