Owner's manual
Chapter 8 - Troubleshooting
8-27
DISPLAY TEST FAILURE SOLUTIONS
KGS or LBS Kilograms or pounds. Default is Lb.
WSVR = 4 Indicates WAVERSAVER that was selected Default is 4.
In Calibration
GRAD Indicates next parameter will be None
graduation size.
1 or 2 or 5 etc. Graduation size calibrated in unit (least Default is 1.
significant digit on display will change by
this amount).
SPAN Indicates next parameter will be Span. None
10000 Span value calibrated in unit. Default is 10,000.
(example)
ZR CNT Indicates next parameter will be A to D
counts representing the Zero Count. --
36780 A to D counts that indicate the calibrated Default is 36780.
(example) Zero.
FS CNT Indicates next parameter will be Full Scale None
Count. 0 in most significant digit indicate
value >1,000,000.
992000 A to D counts that indicate the Calibrated Default is 992000.
(example) Span Value.
SC CAP Indicates next parameter will be Scale None
Capacity.
999999 Scale capacity value calibrated in unit. Default is 10,000.
(example)
0 TOL Indicates next parameter will be Zero None
Tolerance.
10 Zero Tolerance value calibrated in unit. Default is 10.
(example)
AO TOL Indicates next parameter will be None
Auto Zero Tolerance
10 Auto Zero Tolerance set during calibration None