User Manual

79 CHAPTER 6
Mapping
Command Interface
Parameter Numbers, Code Explanations and Valid
Ranges
CAUTION: T
HESE VALUES AND EXPLANATIONS CAN
CHANGE. ALWAYS CHECK ON THE HARDY WEB SITE FOR
THE NEWEST COMMAND INTERFACE LIST BEFORE USING
THE COMMAND INTERFACE.
NOTE: Data is handled based on the method used writ-
ing data to the unit. If data is written using the
Command Interface (See Below) the data is inter-
preted based on the displayed units. However, if
data is directly mapped into the unit, the unit
assumes lbs (pounds) and converts the entered
data to the displayed units.
Parameter
Number
(Hexadecimal)
Code Explanation Valid Range
0001 Operator ID DFD
0002 Instrument ID Max. 19 characters
0003 OK to Fill Timer 0-999
0004
WAVERSAVER
®
0 = None
5 = .25 Hz
4 = .50 Hz
3 = 1.0 Hz
2 = 3.50 Hz
1 = 7.50 Hz
0005 Number of Averages 1-250
0006 Zero Tolerance 0.000001-999999
0007 Units of Measure 0 = lb, 1 = Kg, 2 =
g 3 = oz
0008 Decimal Point 0-5
0009 Total Decimal Point 0-5
000A Grad Size 0=1, 1=2, 2=5,
3=10, 4=20, 5=50,
6=100, 7=200,
8=500, 9=1000
000B Print Total 1 = YES, 0 = NO
000C Auto Print 1 = YES, 0 = NO
000D Motion Tolerance .01-999999
000E Auto-Zero Tolerance .000001-999999
000F Capacity .000001-999999
TABLE 6-2: PARAMETER NUMBER, CODE
EXPLANATION AND VALID RANGES
0010 Infrared Enable 1 = ON, 0 = OFF
0011 Active Target Weight .000001-999999
0012 Active Num Cycles 0 = cont.,
or 1-999999
0013 OK to Fill Input 1 = YES, 0 = NO
0014 Discharge 1 = YES, 0 = NO
0015 Auto Discharge 1 = YES, 0 = NO
0016 OK to Discharge 1 = YES, 0 = NO
0017 Aux Device Time 0-999
0018 Discharge Gate
Proof
1 = YES, 0 = NO
0019 Discharge Gate
Timer (seconds)
0-99
001A Use Auto-Zero 1 = YES, 0 = NO
001B Auto-Zero Toler-
ance Time
.01-9.99
001C Tare Limit 999999.0000
0022 Refill 1 = YES, 0 = NO
0023 Initial Refill 1 = YES, 0 = NO
0024 OK to Discharge
Timer (seconds)
0-999
002A Baud Rate 0 = 300
1 = 1200
2 = 2400
3 = 4800
4 = 9600
5 = 19200
002B Parity 0 = None
1 = Odd
2 = Even
002C Data Bits 0 = 7 bits
1 = 8 bits
0038 Proof Switch 1 = YES, 0 = NO
0039 Gate Timer
(seconds)
0-99
003B Refill Weight .000001-999999
003C Refill Duration Timer 0-999
003D Auto-Tare time 5.0000
0200 Reference Weight 0.000001-999999
(Read Only)
Parameter
Number
(Hexadecimal)
Code Explanation Valid Range
TABLE 6-2: PARAMETER NUMBER, CODE