User Manual

FIG. 6 VERTICAL AND HORIZONTAL ORIENTATION
Ste p 2. When installing firmly push th e mounti ng fe et until y ou h ear a
snapping sound. The snap means they are mou nt ed correctly.
Step 3. After installation give each mounting foot a little tug to make
sure they are seated correctly.
NOTE: There are several horizontal and vertical mounting
options. It is highly reco mmen ded th at at least tw o
mounting feet be used per enclosure.
Step 4. To mount the enclosure onto a DIN rail. Place the mounting
feet on the DIN Rail and firmly press down un til the mounting
feet snap onto the rail.
Step 5. To remove the mounting feet use a finger o n t he clip and gen-
tly pull up on the tab.
NOTE: For Remote Display installation please see Chapter 3,
Installation, of the HI 4050 User’s Guide.
LOAD POINT INSTALLATI ON
FIG. 7 REAR PANEL
FIG. 8
C2
®
Load Point Connectio n
Cable c olo r code for C2 Load Points (left to ri ght facing the rea r panel):
Shie ld Gro un d Wire
•C2- Violet
•C2+ Grey
EXC- Black
•SEN- Brown
SIG- White
SIG+ Green
•SEN+ Blue
•EXC+ Red
Step 1. Remove the factory installed jumpers from the terminal block
if you are connecting an 8 wire cable from the junction box.
(See Fig. 8)
Step 2. Connect the cable (Recommended load cell cable: Hardy
Instruments Part # 6020-0001) wires to the Weigh Scale Input-
terminal blo ck acc ord in g to the cabl e colo r chart.
Step 3. Plug the terminal block into the Weigh Scale Input connector
on the rear panel.
Step 4. For more information concerning C2 Lo ad Point connection,
consult Chapter 3, Installation, of the HI 4050 User Guide.
Non-C2 Load Point Connection
NOTE: Cable Col or Codes vary between vendors, check with your
supplier fo r the Colo r Code f or your Non -C2 load point . Do
not connect wires to the -C2 and +C2.
Step 1. Remove the factory installed jumpers from the terminal block
if you have a 6-wire load cell cable that includes sense wires
from the load cell or junction box.
Step 2. Connect the cable (Recommended load cell cable: Hardy
Instru ments Part # 6020-0001) wires to the Weigh Scale I nput
terminal blo c k accord in g to the manu fa ct urer’s specification .
Step 3. Plug the terminal block into the Weigh Scale Input connector
on the rear panel.