Owner's manual

6
Chapter 2
Front Panel (optional)
Monochrome 480 x 272 LCD display with backlight
Five tactile keys for menu item selection
Load Cell Excitation
5 VDC +/- 1.15 VDC maximum
Isolation from digital section 1000 VDC minimum
C2 Calibration Input
Isolation from digital section 1000 VDC minimum
Cable Lengths
250 feet maximum of C2 authorized cable (Maximum of 4 load sensors) with IT
Junction box
Network Connectivity
Ethernet TCP/IP
Ethernet UDP
Modbus-RTU over RS485
HI 6310 Only
Analog 4-20 mA
Printer port
USB port
Environmental Requirements
Operating Temperature Range
0 to 60
º
C (32
º
to 140
º
F)
Temperature Coefficient
Less than 0.005% of full scale per degree C for Cal-LO and Cal-HI reference points
Storage Temperature Range
-40 to 85
º
C (-40
º
to 185
º
F)
Humidity Range
0-90% (non-condensing)
Maximum Altitude for Installation
2000 Meters (6,562 Feet)
Pending Approvals
UL, CUL and CE
Hazardous Class I, Division 2, Groups A,B,C,D, T4A and Class I, II, III, Division 2,
Groups F, G, T4A