Owner manual

HI 6600 Series Modular Sensor System User Guide
Page | 118
Appendix B
Default Parameter IDs and Values
• • • • • •
Default Parameters and Values Table
Below is a list of parameters, their ID numbers and their defaults for reference.
Menu SubMenu Parameter Name Param ID R/W defaults (value)
Calibration (menu items) Loadcell Sensitivity 0x4081 r/w 4 (3.0 mV/V)
Calibration (menu items) Cal Motion Tolerance 0x4082 r/w 10.00
Calibration C2Cal Ref Weight 0x4101 r/w 0.00
Calibration C2Cal Gravity Correction 0x4102 r/w 1.00
Calibration C2Cal Num Devices 0x4103 r n/a
Calibration HardCal Cal Low Weight 0x4181 r/w 0.00
Calibration HardCal Span Weight 0x4182 r/w 1000.00
Menu SubMenu Parameter Name Param ID R/W defaults (value)
Communication EthernetTCP Enable DHCP 0x3107 r/w 0 (off)
Communication EthernetUDP Hardy Port 0x3181 r/w 1024
Communication ModbusRTU MODBUS Baud Rate 0x3201 r/w 3 (9600)
Communication ModbusRTU MODBUS Parity 0x3202 r/w 1 (even)
Communication ModbusRTU MODBUS Slave Address 0x3203 r/w 3
Communication Scoreboard Scorebaord Baud Rate 0x3281 r/w 3 (9600)
Communication Scoreboard Scoreboard Parity 0x3282 r/w 0 (none)
Communication Scoreboard Scoreboard Mode 0x3283 r/w 1 (Gross weight)
Menu SubMenu Parameter Name Param ID R/W defaults (value)
Display (menu items) Display Mode 0x8083 r/w 0 (gross)
Display (menu items) Display Auto Mode 0x8084 r/w 0 (disabled)
Menu SubMenu Parameter Name Param ID R/W defaults (value)
Filter (menu items) WAVERSAVER 0x2081 r/w 3 (1.0 Hz)
Filter (menu items) Num Averages 0x2082 r/w 10