Owner manual
HI 6600 Series Modular Sensor System User Guide
Page | 79
The following list explains the operation and features available if the correct 4
alphanumeric character
password is entered by the operator.
1)
Keypad Password:
The current keypad lock setting is saved.
The MODE, TARE, and ZERO buttons are unlocked, enabling the operator
to tare or zero the scale.
Pressing the ENTER button a second time returns the keypad lock to its
original setting.
2)
Configuration Password:
The current keypad lock and configuration lock setting are saved.
The TARE and ZERO buttons are unlocked, enabling the operator to tare or
zero the scale.
The CONFIG button is also enabled allowing the operator to open the
configuration menus.
When the operator exits the configuration menu, the display lock and keypad
lock are set to their original settings. If no
changes to the configuration lock
or password parameters were made the configuration lock is also set to its
original
lock settings; otherwise the latest configuration security settings are
used.
The Configuration Lock
While the configuration lock is enabled the Configuration button is disabled, preventing the
operator from viewing or modifying
any instrument parameters.
If the CONFIG button is pressed the “Enter Password” page will appear on the display. At
this level of security the operator can
enter only one possible password for the configuration
lock.
The configuration lock flowchart shows the options and features when the configuration
lock is enabled.