Table of contents Table of contents 1 General information................................................................................................................................. 1.1 Further information........................................................................................................................... 1.2 Notational conventions.................................................................................................................... 1.3 Symbols and signal words.....
PA-100 Power Attenuator
General information 1 General information This user manual contains important information on the safe operation of the device. Read and follow all safety notes and all instructions. Save this manual for future reference. Make sure that it is available to all persons using this device. If you sell the device to another user, be sure that they also receive this manual. Our products and user manuals are subject to a process of continuous development.
General information 1.1 Further information On our website (www.thomann.de) you will find lots of further information and details on the following points: Download This manual is also available as PDF file for you to download. Keyword search Use the search function in the electronic version to find the topics of interest for you quickly. Online guides Our online guides provide detailed information on technical basics and terms.
General information Letterings The letterings for connectors and controls are marked by square brackets and italics. Examples: [VOLUME] control, [Mono] button. 1.3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual. Signal word Meaning DANGER! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided.
General information Warning signs Type of danger Warning – high-voltage. Warning – danger zone.
Safety instructions 2 Safety instructions Intended use This device is used to attenuate the output level of guitar amps. Use the device only as described in this user manual. Any other use or use under other operating conditions is consid‐ ered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
Safety instructions CAUTION! Possible hearing damage With loudspeakers or headphones connected, the device can produce volume levels that may cause temporary or permanent hearing impairment. Do not operate the device permanently at a high volume level. Decrease the volume level immediately if you experience ringing in your ears or hearing impairment. NOTICE! Operating conditions This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture.
Features 3 Features Power soak for tube amplifiers, ideal for use in rehearsal rooms, recording studios and on stage. n n n n n n n n Input power: max.
Connections and controls 4 Connections and controls ö # $ % 1 [Full Power] | LED as overload indicator 2 [Line Level] | rotary control for adjusting the signal attenuation at the line out 12 PA-100 Power Attenuator & ' (
Connections and controls 3 [SPK Level] | rotary control for adjusting the signal attenuation at the speaker out. Turn this control counter-clockwise to reduce the volume of the output signal. The output signal is also being attenuated by approx. 3 dB with an open control ([SPK Level] in position ‘9’)! With a closed control ([SPK Level ] in position ‘0’), a very low signal may remain audible through the connected speakers when the device is used with a very high amp output signal.
Technical specifications 5 Technical specifications Input connections 3 × 1/4" phone socket Output connections 1 × XLR, 3-pin (low-impedance) 2 × 1/4" phone socket Input impedance 4 Ω, 8 Ω, 16 Ω Input power max. 100 W Dimensions (W × H × D) 190 mm × 110 mm × 140 mm Weight 1.
Plug and connection assignment 6 Plug and connection assignment Introduction This chapter will help you select the right cables and plugs to connect your valuable equip‐ ment in such a way that a perfect sound experience is ensured.
Cleaning 7 Cleaning Components Clean the externally accessible device parts regularly. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the device parts. n Clean with a soft dry cloth. n Stubborn stains may be removed with a slightly damp cloth. n Never use cleaners containing alcohol or thinner.
Protecting the environment 8 Protecting the environment Disposal of the packaging mate‐ rial For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging.