Owner's Manual Installation and Operation Model: Oakleaf Non-Catalytic, Top Load, Wood Burning Room Heater Item #1-90-797000 NOTICE DO NOT DISCARD THIS MANUAL • Important operating and • Read, understand and • Leave this manual with maintenance instructions included. follow these instructions party responsible for use for safe installation and and operation. operation. WARNING WARNING Please read this entire manual before installation and use of this wood-burning room heater.
Oakleaf Woodburning Stove Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available. The Oakleaf has huge features in an elegantly small package. With a heating capacity of 1400 to 1600 ft², The Oakleaf takes advantage of Harman’s 30+ years of stove design, technology and manufacturing.
Oakleaf Woodburning Stove TABLE OF CONTENTS Section 1: Listing and Code Approvals A. Appliance Certifications B. Mobile Home Approval C. Glass Specifications D. Electrical Rating E. BTU & Efficiency Specifications Section 9: Service & Maintenance 4 4 4 4 4 A. Soot Formation (Removal) B. General Maintenance Procedures Section 10: Reference Materials A. B. C. D. Section 2: Special Warnings and Notes A.
1 Oakleaf Woodburning Stove Listing and Code Approvals E. BTU & Efficiency Specifications A. Appliance Certification Model: Laboratory: Report No. Type: Standard(s): Oakleaf Woodburning Stove OMNI-Test Laboratories, Inc. 135-S-26-6.2 Solid Fuel Room Heater / Wood Burning Type. UL1482-10, & ULC S627-00 Particulate Emissions Rating: *BTU Input: Heating Capacity: Firebox Size: Fuel: Shipping Weight: This appliance is also approved for installation in a shop. B.
Oakleaf Woodburning Stove 2 Special Warnings and Notes Carbon monoxide, referred to as CO, is a colorless, odorless gas that is produced during combustion of wood and other fuels. CO fumes are toxic and can be fatal. The Oakleaf is a natural draft system which relies on a properly designed chimney to remove CO and other combustion by-products from the stove. Even though this stove is designed to be as safe as possible, it is important that you install a CO detector.
3 Oakleaf Woodburning Stove Getting Started A. Design, Installation & Location Considerations B. Fire Safety 1. Appliance Location Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation.
Oakleaf Woodburning Stove C. Component Locations Top Load Door Top Load Opening Bypass Damper Control Handle Front Load Door Air Control Ash Door Level adjuster Ash Door Latch Front Load Door Latch D. Flue Direction Conversion The Oakleaf features an adjustable flue collar for rear or top exit. Follow these instructions for changing the direction. First, remove the upper rear heat shield by removing 8 tek screws that secure it.
Oakleaf Woodburning Stove E. Pre- Use Check List 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Place the appliance in a location near the final installation and follow the procedures below: Open the appliance and remove all articles packed inside. Inspect all items for shipping damage. Notify dealer of any missing or damaged goods. All safety warnings have been read and followed precisely. This Owner's Manual has been read in it's entirety. Floor protection requirements have been read and followed.
Oakleaf Woodburning Stove 4 Dimensions & Clearances A. Appliance Dimensions 25"(635mm) Air Intake 29.2" (742mm) 10.2" (259mm) 27.2" (691mm) When configured for rear flue; Floor to center of flue measures 23.5" (597mm) NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place of the existing shield. 26.2" (665.5mm) Centered Weight 430 lbs Flue Size 6 inch Log Length Recommended 18" Average Emissions 2.2 Grams Per Hr.
Oakleaf Woodburning Stove B. Clearances To Combustibles CLEARANCE TO COMBUSTIBLES: Vertical Venting Configuration Location A Unit to Side Wall B Unit to Back Wall C Vent Pipe to Side Wall D* Vent Pipe to Back Wall 17" / 432 mm 14" / 356 mm 26.75" / 679 mm *17.5" / 444 mm D* C Pipe clearance may be reduced using double wall or insulated connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines.
Oakleaf Woodburning Stove CLEARANCE TO COMBUSTIBLES: Corner Installation, Vertical Vent Location A Shield Corner to Wall B Vent Pipe to Wall Pipe clearance may be reduced using double wall or insulated connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines. 14" / 356 mm 21.
Oakleaf Woodburning Stove C. Floor Protection Requirements DANGER: The appliance legs may not be removed for installation. Minimum Size floor protection (USA) is 48" Deep By 32.5" Wide. L Floor Protection Requirements J K Millimeters J Sides- USA /CANADA * 8 203 K Front- USA /CANADA * 18 457 8 203 Wall Wall L Rear- USA J Inches L Rear- CANADA * Floor protection for the front and sides as measured from the appliance door opening.
Oakleaf Woodburning Stove 5 The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Chimneys and Venting A. Draft Draft is widely misunderstood. It is important that you, the stove operator, realize that draft is a variable effect, not a given quantity. Stoves and chimneys do not have draft, yet draft is the key to your stove’s performance. Draft is a force, produced by an operating stove and the chimney to which it is attached.
Oakleaf Woodburning Stove Closest Combustible Material Minimum 2" (50mm) Clearance to Brick Liner Chimney Flue Hole with a minimum clearance of 18" (450 mm) between connector and wall. Non-combustible cover, one side only. If two covers are used, each must be mounted on non-combustible spacers at least 7/8" (21mm) away from the wall. 1" (25mm) Clearance Fire Clay Thimble Chimney Connector Masonry Chimney Built to NFPA 211 Specifications.
Oakleaf Woodburning Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height, structural defects, blockages, inadequate clearance to combustibles, unsealed openings into other rooms of the house, signs of creosote or smoke leakage, a loose or absent clean-out door, or absence of a liner. 2.
Oakleaf Woodburning Stove Standard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney Chimney Cap Chimney Sections Attic Radiation Shield Storm Collar Chimney Cap Roof Flashing Roof Radiation Shield Roof Radiation Shield Factory-Built Metal Chimney Sealed Storm Collar Roof Flashing Cathedral Style Chimney Support Minimum Air Space with Chimney Listing Chimney Support Finishing Collar Chimney Connector Chimney Connector The Chimney Connector
Oakleaf Woodburning Stove Chimney Breach Fireplace Conversion with Non-Combustible Wall Minimum Clearance to Unprotected Ceiling 16" Chimney Connector Sealed at Thimble Flue Liner with Required Air Space Three Sheet Metal Screws per Joint of Chimney Connector Airtight insulated Cleanout Mantel and Trim Protection Damper Closed and Sealed with NonCombustible Material.
Oakleaf Woodburning Stove Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection) Flue Liner with Required Air Space Airtight insulated Clean-Out Stainless Steel Chimney Connector Must Extend to Flue Liner Minimum 8" Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with NonCombustible Material Damper Plate is Removed or Fastened in Open Position Listed Fireplace Trim Protection for Reduced Clearance Floor Protection* Combustible Floor *Floor Protection in Accorda
Oakleaf Woodburning Stove Full Relining Fireplace Conversion: Freestanding Appliance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer's instructions on insulation and support UL1777 Insulated Stainless Steel Flex Liner or Other Approved Lining System in Offsets.
Oakleaf Woodburning Stove Chimney Breach Fireplace Conversion with Combustible Wall Minimum Clearance from Chimney Connector to Unprotected Ceiling 16"** Flue Liner with Required Air Space Listed or Approved Thimble Assembly 1"Clearance for Complexity Exterior Chimney or 2" Clearance for Interior Chimney and 2" Clearance for NFPA 211-Type Approved Thimbles Combustible Wall Sheetrock Airtight insulated Clean-out Mantel & Trim Protection Damper Closed and Sealed with Non-Combustible Material.
Oakleaf Woodburning Stove 6 Mobile Home A. Mobile Home Installation CAUTION Mobile home approval - U.S. only. DO NOT INSTALL IN A MOBILE HOME IN CANADA. 1. An outside air inlet must be provided for combustion air, and must remain clear of leaves, debris, ice, and/or snow. The outside air path must be unrestricted while the appliance is in operation. 2. The combustion air intake system must be of metal construction. It must permit zero-clearance to combustible materials, and contain a rodent screen. 3.
7 Oakleaf Woodburning Stove Appliance Set-Up A. Outside Air Attachment B. Leveling the Appliance Parts and Supplies Needed: 1 piece of metal flexible pipe, 4" X needed length. 1 Rodent Screen, and aluminum tape. Plus, a trim ring for finishing around the pipe on the inside wall. To adjust the leveling bolts, you must first loosen the locking nut. Turn the leveling bolt to the desired position, and tighten the locking nut against the cast iron leg. 1.
Oakleaf Woodburning Stove D. Optional Blower Installation E. Optional Rear-vent Rear Shield The optional blower kit #1-00-797032 installs easily to the rear of the Oakleaf. Hold the blower assembly into place and secure it with the two bolts provided. You'll need a 3/8" wrench or socket to tighten the bolts. Whenever a rear vent configuration is used, the upper rear heat shield, #1-00-797066 must be purchased and installed, to accomodate the flue collar.
8 Oakleaf Woodburning Stove Operating Instructions CAUTION: Approved for use with wood fuel only. The use of any other fuel will void the product warranty and may cause damage to the appliance and/or your home. Always wear fire retardant gloves when operating the stove. SAFETY NOTICE Warning IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW I N S TA L L AT I O N D I R E C T I O N S .
Oakleaf Woodburning Stove 2. Doors Your stove has a large glass-paneled door for loading and fire viewing, a separate smaller door for removing ashes and a top loading door. Front Door Before opening, always check for wood, embers, or ash that may be ready to fall out of the door. To open the glass door, open the bypass damper first, then turn the handle clockwise and pull out; to close the door, push the door closed with the handle in the open position, then turn, counter-clockwise, to engage the latch.
Oakleaf Woodburning Stove D. User Controls Two important controls - the damper bypass handle and the air control lever regulate the operation and output of the stove. To open the top or front loading door, you must open the damper bypass, or smoke will come in the room. In this mode of operation the combustion gases go directly from the main combustion chamber to the flue collar and exit into the chimney. NOTE: The bypass damper must be open for smokeless loading.
Oakleaf Woodburning Stove This will begin the highly efficient mode of operation where the exhaust gases get re-burned in the secondary combustion package. If you cannot achieve a charcoal bed within the first 15 to 20 minutes, your wood is likely too wet, and you may need to burn the fire longer and/ or hotter to compensate for the extra energy needed to drive out the moisture.
9 Oakleaf Woodburning Stove Solid fuel burning spave heaters must be cleaned regularly, as soot, ash and creosote may accumulate. Service & Maintenance A. Creosote- Formation and Need For Removal; When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on the flue lining.
Oakleaf Woodburning Stove B. General Maintenance Procedures 1. Ash Removal • Frequency: As needed / Every day or two • By: User Wear Leather Gloves To Prevent Skin Burns! Open the ash removal door by lifting upward on the latch handle, then swing the door open. Pull the ash pan out of the firebox, using the lip on the front of the pan. Once the ash pan is removed from the stove, you can flip the carry handle up for convenience.
Oakleaf Woodburning Stove 3. Firebox • Frequency: As necessary / Yearly • By: User 5. Chimney Connector • Frequency: As necessary / Yearly • By: Qualified Service Technician / User Cleaning the firebox and internal heat exchange surfaces is recommended to maintain thermal efficiency. Depending on the quality and quantity of fuel being used, you may want to perform this cleaning monthly. At the end of the burn season, brush and clean all sections of chimney connector pipe.
Save These Instructions Power Cord Variable Speed Switch 3-90-798 White Wire Grounded to housing Black Wire Blower Thermostat 10 Rocker Switch Oakleaf Optional Blower Kit #1-00-797032 - WIRING DIAGRAM Oakleaf Woodburning Stove Reference Materials Dry Seasoned Wood Only! 31 1 2
Oakleaf service parts Beginning Manufacturing date: sept 2010 Ending Manufacturing date: active Cast Iron Wood stove 1-90-797000-1 (Black), ((sept 2010 thru june 2011)--1-90-797000-2 (Charcoal), 1-90-797000-3 (goldenfire)) 3 1 4 5 10 11 2 7 6 9 27 12 8 13 14 16 28 25 21 15 23 26 22 24 18 19 17 20 part number list on following page.
Oakleaf service parts Beginning Manufacturing date: sept 2010 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Oakleaf service parts Beginning Manufacturing date: sept 2010 Ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Manufactured by: HarMan HOMe HeatInG MOdel: Oakleaf u.S. envIrOMental PrOtectIOn aGency Meets EPA particulate matter (smoke) control requirements for noncatalytic wood heaters built on or after July 1, 1990. SMOke 0 Grams Per Hour 8.5 effIcIency 50% 60% 70% 80% 90% 100% Wood heaters with higher efficiencies cost less to operate. Heat OutPut 9,600 to 24,700 btu use this to choose the right size appliance for your needs. aSk dealer fOr HelP.
Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY CONDITIONS: • • • • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. This warranty is only valid while the HHT appliance remains at the site of original installation. Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier.
Oakleaf Woodburning Stove Service & Maintenance Log Date Of Service Performed By 38 Dry Seasoned Wood Only! Description Of Service 3-90-798 Save These Instructions
At Harman, we build each product to a standard, not a price. This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.