Owner's Manual
12
TL2.0 Woodburning Stove
Dry Seasoned Wood Only! Save These Instructions3-90-08560
C. Floor Protection Requirements
Minimum Size oor protection (USA) is 48" Deep By 32.5"
Wide.
Floor Protection Requirements
If the appliance is being installed on a combustible oor,
non-combustible oor protection must be installed. In all
installations, the area under and around the stove must
be protected from falling ash and live coals. The area
under a horizontal run of chimney connector must also be
protected, extending two (2) inches (51mm) to each side of
the horizontal connector.
Further guidelines for oor protection are as follows: In the
U.S. the oor protector must be completely under the stove,
and extending 18" in front of the door opening, 8" to each
side of the door opening, and 8" to the back.
In Canada, the oor protection must extend 18" (457mm) in
front of the door opening, and 8" (203mm) to each side of
the appliance, and to the rear.
* Floor protection dimensions for the front and sides are
measured from the appliance door opening in The United
States. In Canada, the side dimension is measured from the
widest part of the appliance.
Minimum 60" corner oor protection (CANADA).
JJ
K
L
54"
54"
L
J
Floor Protection
Requirements
Inches Millimeters
Sides- USA /CANADA *
Rear- USA
8 203
8 203
L
Rear- CANADA
Wall Wall
K
Front- USA /CANADA *
16 457
Alternate oor protector dimension may be used as long
as they satisfy the measurement requirements shown
above.
Minumum size oor protection for a corner installation
hearth pad is 54" x 54" (USA ONLY).