Installation & Operating Manual The Harman Exception Wood Stove (Model TL200) R7 SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. FOR USE IN THE U.S. AND CANADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN EXCEPTION MODEL TL200 STOVE IS NOT PROPERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.
Exception TL200 Wood Stove Introduction Thank you for purchasing the Harman Exception Wood Stove. With the Exception you will notice even heat throughout your home and long burn times. This is possible because of our exclusive Harman Afterburner Combustion System which takes unburned gases into the afterburner chamber where they are mixed with air and burned at very high temperatures.
Exception TL200 Wood Stove Specifications 3.5" 3.75" Weight 440 lbs Flue Size 6 inch Log Length Recommended 18" with 20" Max Heating Capacity 1500 to 2800 sq. ft. Average Emissions 4.4 Grams Per Hr. Emissions on Low 2.25 Grams Per Hr.
Exception TL200 Wood Stove Specifications Top Load Door Top Load Opening Front Load Door Combination Top Load Door and Damper Arm Grates Side Shield Andirons Front Load Door Latch Ash Door Latch Ash Door 4
Exception TL200 Wood Stove Operation General Considerations Draft Before you install and operate your Exception wood stove, please read the entire contents of this manual. Pay particular attention to the explanation of draft and its effect on stove performance in the venting section. By following the installation and operating guidelines, you will ensure proper draft and gain maximum efficiency and enjoyment from your stove. Fuel Your Exception burns wood very efficiently.
Exception TL200 Wood Stove Operation The Combustion Process Controls Combustion in your Harman Exception is controlled very precisely. During a wood fire, primary combustion air enters the bottom of the stove, is directed up to the top of the load door and then down past the glass, finally entering the combustion chamber.
Exception TL200 Wood Stove Operation Air Control Building and Maintaining the Fire The air control lever is located directly below the ash lip of the stove. Using this lever you will be able to vary the amount of air delivered to the fire, creating a range of heat outputs. The low heat output setting is to the left, and high is to the far right. Do not, under any circumstances, alter the configuration or operation of the air control lever.
Exception TL200 Wood Stove Operation As you begin to operate your stove at higher temperatures, you will notice a “hot” or unpleasant smell; this is just the paint going through the curing process, and will disappear after a few fires. The following guidelines for air settings can be used for wood burning; as you become familiar with your stove, you will know which settings best heat your home. • Minimum burn rate - air control fully to left. • Medium low burn rate - air control moved 1" to right.
Exception TL200 Wood Stove Maintenance Like all fine equipment, your Exception requires some routine maintenance and inspection. Follow the guidelines in this section to guarantee safe, efficient operation. The Stove Surface The stove’s exterior surface should be dusted periodically with a soft cloth. For more thorough cleaning, wait until the stove is cool before using a damp cloth to clean any blemishes. The Door If you have a gold plated front door it should never be buffed or polished.
Exception TL200 Wood Stove Maintenance Gaskets The Chimney System Gaskets are used at strategic positions when building the Harman Exception for controlling the path that incoming and outgoing air and gases take through the stove. You must check these gaskets from time to time, and replace them when necessary. The gaskets are made of fiberglass of different sizes (obtainable from Harman Stove Company) and are fixed in place with a high temperature stove gasket cement.
Exception TL200 Wood Stove Installation DO NOT INSTALL IN A SLEEPING ROOM Assembly Outside Air (optional) Blower (optional) The Exception is designed to accommodate the use of outside air introduced directly to the stove. The opening is located at the back of the stove behind the pedestal. An outside air connector plate attaches over this opening, using two 1/4-20 x 1/2"” hex head bolts.
Exception TL200 Wood Stove Installation Floor Protection Parallel versus Corner Installations In all installations, the area under and around the stove must be protected from falling ash and live coals. The area under a horizontal run of chimney connector must also be protected . This protector must be of noncombustible material, and positioned as shown in the accompanying illustration.
Exception TL200 Wood Stove Door Assembly/Installation Tips Door Glass Paw Bolt • Be sure that the door glass is installed in the door with • The paw bolt should be turned into the door from the the label, located on the glass, on the external side of the door. • Rope the glass carefully to insure proper sealing. • Apply the rope exactly along the edge of the external face of the glass, not overhanging or pressed too far in from the edge. • Make sharp 90o turns at the corners.
Exception TL200 Wood Stove Exception Linkage Installation Before side shield is in place. Step 1: Remove left side shield The side shield has tabs on it that latch into holes on the side of the stove. This makes removing the side shield easy. • Lift up on the side shield then pull out. slots for side shield tabs Step 2: Install the drive arm • With left hand, slide new drive arm through hole in side of stove.
Exception TL200 Wood Stove Exception Linkage Installation, cont'd Before side shield is in place. Step 3: Install the top lift arm • Tighten the 1/4-20 x 5/8 button head allen bolt. Bolt into the tab on the underside of the top lid. This bolt can be tightened fully. (See Fig. 6 & 7) • Slide the top lift arm onto the shoulder pin on the drive arm. Check positioning of top lift arm. (See Fig. 5) • Using the 1/4-20 lock nut, secure the top lift arm to the lid.
Exception TL200 Wood Stove Exception Linkage Installation, cont'd 1/4 x 20" Self Locking Nut Lift Lug 1/4 x 20" Button head Allenbolt Top Lift Arm Drive Arm Assembly Outside Damper Arm Shoulder Pin Pivot Arm Figure 7 16
Exception TL200 Wood Stove Venting Chimney Connectors and Chimneys Draft Draft is widely misunderstood. It is important that you, the stove operator, realize that draft is a variable effect, not a given quantity. Stoves and chimneys do not have draft, yet draft is the key to your stove’s performance. Draft is a force, produced by an operating stove and the chimney to which it is attached.
Exception TL200 Wood Stove Venting The Chimney The Exception must be installed into a chimney approved for use with solid-fuel appliances. In the U.S., the Exception must be connected to (1) a prefabricated chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Residential Type and Building Heating Appliances, UL 103, or (2) a code-approved masonry chimney with a flue liner.
Exception TL200 Wood Stove Venting Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height, structural defects, blockages, inadequate clearance to combustibles, unsealed openings into other rooms of the house, signs of creosote or smoke leakage, a loose or absent clean-out door, or absence of a liner.
Exception TL200 Wood Stove Venting - Mobile Homes Moblie Home Installations Mobile home installations must use approved factory-built chimneys tested and listed for this specific use, to either of the high temperature standards, ULC S-629 or UL 103. Any components used to install the chimney must be listed for this use and supplied by the chimney manufacturer. Do not substitute makeshift compromises. In Canada, chimney connectors must be tested and listed to the standard in CAN/ULC-641-M87.
Exception TL200 Wood Stove Exception Parts List 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44.
6 4 1 5 3 2 7 41 19 20 11 22 21 13 8 18 17 15 23 30 9 10 16 14 34 32 35 31 33 28 39 24 40 36 27 38 37 Exception TL200 Wood Stove Exception (TL200) Parts 22
Exception TL200 Wood Stove Harman Gold Warranty HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for a period of 3 years from the date of sales invoice.