24VDC CLEAR Lens Indoor Strobe Current Ratings
GEC24 and
GES24 Series
Available Candela
GEC3-24 and
GES3-24 Series
Available Candela
Strobe
Candela
Regulated 24VDC
Max. Operating
Current(mA)
Regulated 24VFWR
Max. Operating
Current (mA)
1
15 42 77
15/75 67 113
30 58 102
60 97 161
75 116 225
110 161 256
177 213 341
WGEC24, WGES24, WGECA24, WGESA24, WGECB24, WGESB24, WGECG24, WGESG24, WGECR24, WGESR24 PRODUCT INFORMATION
Models Color Lens
WGECA24, WGESA24 Amber
WGECB24, WGESB24 Blue
WGECG24, WGESG24 Green
WGECR24, WGESR24 Red
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM
O
PERATION.
1
W
hen using products manufactured after 7-1-10, these values are to be used when calculating current draws.
12VDC CLEAR Lens Strobe Current Ratings
Use with GEC3-12 and GES3-12 Products
Candela
Regulated 12VDC
Max. Operating
Current (mA)
Regulated 12VFWR
Max. Operating
Current (mA)
1
15 92 145
30 141 224
60 260 459
75 312 460
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE
STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.
1
When using products manufactured after 7-1-10, these values are to be used when calculating current draws.
24VDC CLEAR & AMBER Lens Outdoor
Strobe Current Ratings
Use with WGEC24, WGES24,
WGECA24, WGESA24 Products
Candela
Regulated 24VDC
Max. Operating
Current (mA)
Regulated 24VFWR
Max. Operating
Current (mA)
1
75 170 263
24VDC BLUE, GREEN & RED Lens Outdoor
Strobe Current Ratings
Use with WGECB24, WGESB24, WGECG24,
WGESG24, WGECR24, WGESR24 Products
Candela
Regulated 24VDC
Max. Operating
Current (mA)
Regulated 24VFWR
Max. Operating
Current (mA)
1
75 164 278
AMBER Lens Indoor Strobe Current Ratings
Use with GECA24 and GESA24 Products
Candela
Regulated 24VDC
Max. Operating
Current (mA)
Regulated 24VFWR
Max. Operating
Current (mA)
1
15 47 82
30 64 112
60 113 178
75 145 213
110 178 259
GECA24, GESA24, GECB24, GESB24, GECG24, GESG24, GECR24, GESR24 PRODUCT INFORMATION
BLUE, GREEN & RED Lens Indoor
Strobe Current Ratings
Use with GECB24, GESB24, GECG24,
GESG24, GECR24, GESR24 Products
Candela
Regulated 24VDC
Max. Operating
Current (mA)
Regulated 24VFWR
Max. Operating
Current (mA)
1
15 105 164
30 130 196
60 203 325
75 243 355
110 310 491
Models Color Lens
GECA24, GESA24 Amber
GECB24, GESB24 Blue
GECG24, GESG24 Green
GECR24, GESR24 Red
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE
STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.
1
When using products manufactured after 7-1-10, these values are to be used when calculating current draws.
Horn Decibel Levels
Horn Current Ratings Over
Input Voltage Range of 16-33V
Horn Mode
Minimum SPL
at 10Ft. Per
ANSI/UL 464
(HIGH)
Minimum SPL
at 10Ft. Per
ANSI/UL 464
(LOW)
Regulated 24VDC
Max. Operating
Current (mA)
HIGH Setting
Regulated 24VFWR
Max. Operating
Current (mA)
HIGH Setting
Temp 3 2400Hz 78 dBA 71* dBA 28 48
Temp 3 Mechanical 76 dBA 70* dBA 25 44
Temp 3 Chime 70* dBA 66* dBA 15 30
Continuous 2400Hz 81 dBA 74* dBA 28 48
Continuous Mechanical 80 dBA 72* dBA 25 44
Continuous Chime 70* dBA 66* dBA 15 30
Whoop 82 dBA 69* dBA 56 62
HORN DECIBEL AND CURRENT RATINGS PRODUCT INFORMATION
Horn Decibel Levels
Horn Current Ratings Over
Input Voltage Range of 8-17.5V
Horn Mode
Minimum SPL
at 10Ft. Per
ANSI/UL 464
(HIGH)
Minimum SPL
at 10Ft. Per
ANSI/UL 464
(LOW)
Regulated 12VDC
Max. Operating
Current (mA)
HIGH Setting
Regulated 12VFWR
Max. Operating
Current (mA)
HIGH Setting
Temp 3 2400Hz 76 dBA 69* dBA 29 48
Temp 3 Mechanical 75 dBA 68* dBA 26 45
Temp 3 Chime 62* dBA 60* dBA 13 24
Continuous 2400Hz 79 dBA 74* dBA 29 48
Continuous Mechanical 78 dBA 72* dBA 26 45
Continuous Chime 63* dBA 61* dBA 13 24
Whoop 78 dBA 71* dBA 55 61
NOTICE:
THE THREE PULSE TEMPORAL PATTERN IS TO BE USED FOR EVACUATION USE ONLY.
THE SOUND OUTPUT FOR THE TEMPORAL 3 TONE IS RATED LOWER SINCE THE TIME THE HORN IS OFF IS AVERAGED INTO THE SOUND OUT PUT RATING. WHILE THE HORN IS PRODUCING A TONE
IN THE TEMPORAL 3 MODE ITS SOUND PRESSURE IS THE SAME AS THE CONTINUOUS MODE. UNITS HAVE BEEN TESTED TO 0°C, 49°C AND 93% HUMIDITY.
* Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 sound level required for public mode fire protection service.
These settings are acceptable only for private mode fire alarm signaling use. Use the high dBA setting for public mode applications (the chime tone is always private mode).
550-0011
Page 2
Strobe light can not be seen when objects such as doors, furniture or walls block strobe light.
NOTICE:
THE VISUAL SIGNAL MUST BE IN THE DIRECT VIEWING AREA OF THE OCCUPANT IN ORDER TO BE SEEN.
VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING IMPAIRED. VISUAL SIGNALS MAY NOT BE THE PREFERRED METHOD
FOR NOTIFYING ALL HEARING IMPAIRED INDIVIDUALS.
THE STROBE LIGHT MUST BE SEEN BY THE SLEEPING PERSON. IF THE PERSON HAS HEAD TURNED OR OTHERWISE UNABLE TO BE ALERTED BY VISUAL, THE STROBE