Installation Instructions

IntegrationandTest,RBS884Pico(850MHzand1900MHz)
! (EM-RTT) CONTROL !
RISPI:TSLOT1=RILT-450-00, TSLOT2=RILT-461-00,
NAME=CEQ3584CTRL; !DCCH !
RISPI:TSLOT1=RILT-450-01, TSLOT2=RILT-461-02,
NAME=CEQ3585CTRL; !MVC !
RISPI:TSLOT1=RILT-450-02,
TSLOT2=RILT-461-04, NAME=CEQ3586CTRL; !MLOC !
RISPI:TSLOT1=RILT-450-03, TSLOT2=RILT-461-06,
NAME=CEQ3587CTRL; !MVER !
! (ETB-RTT) SPEECH !
Note: The numbering for the speech timeslots on a T1 PCM link st
arts
at 01 and ends with 24 for a total of 24 timeslots. However,
only 23 timeslots can be used for speech on the first T1 PCM
link because timeslot 09 is used for the control time
slot. The
numbering for the speech timeslots on an E1 PCM link starts at
00 and ends with 31 for a total of 32 timeslots. However, only
30 timeslots can be used for speech on the f
irst E1 PCM link
because timeslot 00 and 14 are used for the control timeslot. For
additional information about the T1 and E1 PCM links, see
Section5.11.1onpage5-62.
RISPI:TSLOT1=RILT-448-01, TSLOT2=RILT-461-01,
NAME=CEQ3584MBLT1248;
RISPI:TSLOT1=RILT-448-02, TSLOT2=
RILT-461-03,
NAME=CEQ3585MBLT1249;
! RH-2 !
! (EM-RTT) CONTROL !
RISPI:TSLOT1=RILT-451-00, TSLOT2=RILT-461-08,
NAME=CEQ3592CTRL; !DCCH !
RISPI:TSLOT1=RILT-451-01, TSLOT2=RILT-461-10,
NAME=CEQ3593CTRL; !MVC !
RISPI:TSLOT1=RILT-451-02,
TSLOT2=RILT-461-12,
NAME=CEQ3594CTRL; !MLOC !
1532-AE/LZB 119 3834 Uae Rev PA4 2001-04-04 5-131