Installation Instructions

IntegrationandTest,RBS884Pico(850MHzand1900MHz)
2. Check that the software version and the revision state reported
corresponds to the information received from Project or MSC Manager.
Note: If an update is needed, check first if the new
software version is available in the MSC Data Store
(command
MBDSP
). If not, load the new software to
the MSC, and then to the RBS. Refer to MBS Job
Procedure MTBS Device Loading Administration
(1546FCDU 104 505 Uae). The new software is
loaded to the RBS with the
MBDFL
command for
TRXs and the
MBDPL
command for other devices.
3. Check the printout and record the result in the Test Record.
Note: If fault code 131 is obtained, repeat the command for
the device in question.
8.2 Self-Test of TRX and MBTRAC/MBTRC Devices: Pico 8
50/1900 MHz
Prerequisites
1. All devices must be manually blocked and may not be test blocked or
seized by another user. The devices mu
st also be fully connected.
Self-test Devices
2. Self-test the TRX and MBTRAC/MBTRC devices:
MBSDI
Example 5-2: MBSDI:dev=mbtrx-3;
This initiates a test of up to 16 devices in the Mobile Telephony
Base Station subsystem. One command at a time can be
processed.
It is possible to specify a test case in the command with the
parameter TCASE. If the device under test is a TRX operating
in MLOC or MVER mode, TCASE must be set to 1. If the
parameter TCASE is omitted, the default test case 0 will be used.
1532-AE/LZB 119 3834 Uae Rev PA4 2001-04-04 5-69