User Manual

MM102225V1, Rev. B
40
SYSTEM
COMMUNI-
CATIONS
ACTION MISCELLANEOUS
8.
The photograph to the right shows the
in-rack connection point for T1
communications.
The destination of this connection will
vary by site; however, verify that a
modular style plug wired (T568B) is
used to connect the site communications
interface with the base site T1.
If equipped with ISM Backhaul, the
Orange cable is the 10BaseT connection
to the ISM Backhaul Router.
Note
: Actual cables may be different
colors
.
RECEIVE
ANTENNA
CONNECTION
ACTION MISCELLANEOUS
9.
The photograph to the right shows the
in-rack connection point for the system
receive antenna. Verify that the jumper
cable to the receive antenna is present
and disconnect it from the receive input.
Note
: This is only for Tower Top
Amplifier sites.
TTA
CONTROL
CABLE
ACTION MISCELLANEOUS
10.
Ensure that the 5-conductor Tower Top
Amplifier control cable is connected as
shown in the photo to the right.
Note
: The connector is installed in the
field. To solder the connector to the
cable, refer to APPENDIX A
.