User Manual

MM102225V1, Rev. B
48
STEPS ACTION
MISCELLANEOUS
6.
Record the power level as indicated in
the HP 8920 Spectrum Analyzer Lvl
field. Enter this value in the TTA Gain
table, column 2 for TTA “On”
8
.
7.
Turn the Power Switch on the front of
the TTA Control Panel to the “Off”
position.
8.
Record the power level as indicated in
the HP 8920 Spectrum Analyzer Lvl
field. Enter this value in the TTA
Amplifier Gain table, column 2 for TTA
“Off”.
9.
Subtract the recorded “Off” Lvl from the
“On” Lvl.
10. Record the result (gain) in the table.
11.
Reconnect the Jumper disconnected in Step 3
that goes to the TTA “To RECEIVE
MULTICOUPLER” port.
8
Refer APPENDIX L- RECORDED DATA SHEET