User Manual

MM102225V1, Rev. B
63
Continued
STEPS ACTION MISCELLANEOUS
Data in Interval 14:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0
Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err
Secs, 0 Unavail Secs
Data in Interval 15:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0
Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err
Secs, 0 Unavail Secs
Data in Interval 16:
35361 Line Code Violations, 46606 Path Code
Violations
1 Slip Secs, 13 Fr Loss Secs, 1 Line Err Secs, 0
Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err
Secs, 13 Unavail Secs
Total Data (last 16 15 minute intervals):
35361 Line Code Violations, 46606 Path Code
Violations,
1 Slip Secs, 13 Fr Loss Secs, 1 Line Err Secs, 0
Degraded Mins, 0 Errored Secs, 0 Bursty Err
Secs, 0 Severely Err Secs, 13 Unavail Secs
buck40sas#
7.4 FINAL DEPARTURE CHECK
Objective: To ensure that the site is ready for on-line operation and that it can recover
automatically from a catastrophic power failure.
Required Test Equipment
:
PC with suitable console application
Cisco “Black” Cable
Cisco RJ45 to DB-9 adapter