User Manual

MM102225V1, Rev. B
84
APPENDIX F
TYPICAL BASE STATION CONFIGURATION
27
manadabs2> at&v
BSC INFORMATION: S/N: 000000010005
BSC INFORMATION: BSC S/W Version: BSC-1000 Version OTP 4.00 Sep 28
1999 14:58:02
BSC INFORMATION: BSC H/W Version: 50 MHz NGP Rev B with 1M of
Memory
BSC INFORMATION: M/A-COM HPA Version: 0.01e
BSC INFORMATION: M/A-COM HPA Product String: 13-09-99 (0x01, 0x02)
BSC INFORMATION: M/A-COM HPA Serial Number: 00000101
BSC INFORMATION: MACOM BSX Version: 802: 19 09/03/99
BSC INFORMATION: MACOM BSX Serial Number: 000000010004
Switch to Another Process:
BSC I/P Address: 172.18.16.168
MDIS I/P Address: 172.18.16.200
MDIS PORT: 16962[4242]
Voice Grant Timeout: 0[0]
Null Voice Frame Limit (missed end): 15[f]
Null Voice Frame Limit (after grant): 15[f]
Null Voice Frame Limit (after trunk): 20[14]
MSF Pause Interval: 3600[e10]
MSF Pause Duration: 0[0]
Set Channel Characteristics: MANA2[0 698]: Col:[1 4]/4/2 402 2 0
(0.0000,0.0000)
Change Slip Interface Rate: 38400[9600]
RSSI Hysteresis Value: 8[8]
RSSI Scan Time: 90[5a]
RSSI Scan Delta: 8[8]
RSSI Average Time: 5[5]
BLER Threshold: 10[a]
BLER Average Time: 5[5]
CBLER Threshold: 20[14]
CBLER Average Time: 10[a]
RRM CSI Epoch: 60[3c]
27
Taken from M/A-COM, Inc. Drawing No. GTP-0296, Rev. A.