User Manual

MM102365V1 Rev. B
6.3 POWER/FIBER OPTIC CABLE INSTALLATION
This section covers installing the Power/Fiber Optic cable assembly between the ISM Tower Top Radio
enclosure and the shelter demarcation point.
In addition to providing data communication, the Power/Fiber Optic cable assembly also supplies power
to the ISM Tower Top Radio from the Backhaul Router.
CAUTION
Fiber Optic Cable Assembly:
The cable assembly is made with non-conducting materials that can withstand a maximum
crush resistance of 50 lbs.
End pieces and connectors: These components are easily damaged. The bend radius should
be not less than 1.5 in. for this section of the cable assembly.
CAUTION
Weather resistant section: The bend radius should be not less than 6 in. for this section of
the cable assembly.
The assembly must be supported to provide strain relief for the light and fragile ends of the
cable that mount onto the ST connectors on the rear of the Backhaul Router. It must also
have strain relief to support its weight. The cable is not plenum rated. It supports a
maximum hang weight of 200 lb. Maximum hoist length is 1000 ft.
The Power/Fiber Optic cable assembly is available in a number of different lengths. Select the
appropriate length, from Table 6-3, that meets the installation requirements.
Table 6-3: Power/Fiber Optic Cable Assembly Lengths
PART NUMBER LENGTH (FEET)
MAIR0S0002-00006 6
MAIR0S0002-00010 10
MAIR0S0002-00025 25
MAIR0S0002-00050 50
MAIR0S0002-00100 100
MAIR0S0002-00140 140
MAIR0S0002-00200 200
MAIR0S0002-00250 250
MAIR0S0002-00300 300
MAIR0S0002-00350 350
MAIR0S0002-00400 400
MAIR0S0002-00450 450