User Manual

Com-Net Ericsson Critical Radio Systems, Inc. 6
P.O. Box 2000
Lynchburg, Virginia 24501 MM101030V3
1-800-528-7711 (Outside USA, 804-592-7711) Printed in U.S.A.
**Example: 450 MHz Band, 40 Watts and 2.5 dBd gain >>> follow 40 Watt row to 3 dBd
column, which yields 83 cm (33 in) as the MPE Radius.
MPE Radii for Occupational/Controlled Exposure: VHF Band (136 - 174 MHz
1
)
Power
3
dBd Antenna Gain
4
(Watts)
0 1 2 3 4 5 6
cm
in cm
in cm
in cm
in cm
in cm
in cm
in
20 51 20 57 23 64 25 72 28 81 32 91 36 102
40
30 63 25 70 28 79 31 88 35 99 39 111
44 125
49
40 72 28 81 32 91 36 102
40 115
45 128
51 144
57
MPE Radii for Occupational/Controlled Exposure: UHF Band (450 - 512 MHz
2
)
Power
3
dBd Antenna Gain
4
(Watts)
0 1 2 3 4 5 6
cm
in cm
in cm
in cm
in cm
in cm
in cm
in
20 42 16 47 18 53 21 59 23 66 26 74 29 83 33
30 51 20 57 23 64 25 72 28 81 32 91 36 102
40
40 59 23 66 26 74 29 83 33 93 37 105
41 118
46