User Manual

28
Alarm (Horn) Relay Kit - 19A705499P1
To connect the alarm relay kit, the radio option cable (RPM 113
7674/1) must be installed and connected to the radio. The alarm
relay kit option consists of the following items:
!
Relay (19A149299P1)
!
Fuse holder
!
Fuse, 1 amp, 250 volt
!
4 feet red wire, AWG #18 with Ring Tongue Terminal for 3/ 8
stud
!
6 feet black wire, AWG #18 with Molex #39- 00- 0060 terminal
!
(5) Insulated 1/ 4 inch spade tab receptacles
!
Ring Tongue Terminal for 3/ 8 inch stud
!
#8 x 3/ 4 long Type A sheet metal screw
!
Nut Plate for #8 screw
To install the Alarm (Horn) Relay Kit
1. Fasten the relay in the desired location, close to the voltage
source, using one #8 x 3/ 4 inch self- tapping screw.
2. Crimp an insulated 1/ 4 inch spade tab receptacle to one end of
the #18 red wire.
3. Connect the receptacle to relay lug #86. Cut the red lead so the
fuse assembly is close to the voltage source. Install the fuse
holder. Attach the other end of the fuse lead to the voltage source
with appropriate hardware. See Figure 12.
4. From the radio option cable, take the green/white wire and crimp
an insulated 1/ 4 inch spade tab receptacle. Connect the
receptacle to relay lug #85.
5. Connect the horn or light circuit to lugs #30 and #87 (not 87a)
using the insulated 1/ 4 inch spade tab receptacles.
#
The relay contact make/ break current and voltage rating is
30 amps at 16 volts.