Installation Manual

32
Typical Desktop Base Station Antenna Installation
For desktop base station configurations, a typical building roof
top/tower installation may be used.
The Maximum Permissible Exposure limit is a radius of 77
inches (or 195 cm) for typical desktop base station configurations
per OET Bulletin 65 of the FCC. This estimate is made using the
maximum capable transmit power of the radio, an antenna with
a maximum gain of 6 dBd, and a maximum 50% transmit duty
cycle (due to the push-to-talk status of this mobile).
Noise Suppression Kit - Option KMPD1A (19A148539G1)
Refer to the noise suppression kit option installation manual that is
included with this option.