User Manual
15
RF Power Tracking Data for Resetting in the Field
800 MHz Band:
•
6-12 watts, low power J
AGUAR
725M: no resetting of RF power
tracking data is needed.
•
17.5-35 watts, high power J
AGUAR
725M (repeater input band 806-825
MHz): RF power tracking data is reset as follows:
1. The RF Power tracking data shown in the “350” row under the “TX
Power Levels” columns must be adjusted down to 27
±
0.5 watts.
This same tracking data should be copied into the “300” row under
the “TX Power Levels” columns.
2. This will set the upper limit of the 800 MHz mobile in the repeater
input band to a rated RF power of 25 watts (with an actual RF
power setting level of 27
±
0.5 watts).
The 800 MHz RF power tracking data settings are listed in MM101260V1
under the sections for TRACKING DATA, TEST FREQUENCIES, &
SETTING TRACKING DATA. Tracking data frequencies are listed in
Table 2 in the TX RPT INPUT column.
•
15-30 watts, high power J
AGUAR
725M (repeater talkaround band 851-
870 MHz): RF power tracking data is reset as follows:
1. The RF Power tracking data shown in the “30” row under the “TA
TX Power Levels” columns must be adjusted down to 27
±
0.5
watts. This same tracking data should be copied into the “35” row
under the “TA TX Power Levels” columns.
2. Change the “30” & “35” row labels to “25”.
3. This will set the upper limit of the 800 MHz mobile in the repeater
talkaround band to a rated RF power of 25 watts (with an actual RF
power setting level of 27
±
0.5 watts).
The 800 MHz RF power tracking data settings are listed in MM101260V1
under the sections for TRACKING DATA, TEST FREQUENCIES, &
SETTING TRACKING DATA. Tracking data frequencies are listed in
Table 2 in the TX TALK AROUND column.