Maintenance Manual LBI-38812K EDACS Interface Panels 19D904009G1-G32 TABLE OF CONTENTS EDACS Interface Module ...................................... LBI-38813 PTT Module............................................................. LBI-38816 EDACS CTIS Module ........................................... LBI-38818 Power Monitor for Simulcast ................................... LBI-38819 EDACS Interface VAX Site Controller ................. LBI-38943 Power Monitor / Channel Select Module .................
MANUAL REVISION LBI-38812J – Added EDACS Interface Panels 19C904009G31 and G32 used in SitePro applications. Updated parts list and all drawings to the latest revision (Revision 5). Reformatted manual for M/A-COM Private Radio Systems, Inc. LBI-38812K – Added revised drawing, 19D904009 ( Revision 7), and safety information • • • • SAFETY NOTICE The means of disconnecting power from a station cabinet is the cabinet power supply plug.
TABLE OF CONTENTS TABLE OF CONTENTS 1.0 Page SPECIFICATIONS ................................................................................................................................................ 4 2.0 PANEL DESCRIPTIONS ...................................................................................................................................... 5 3.0 MODULE DESCRIPTIONS....................................................................................................................
SPECIFICATIONS 1.0 SPECIFICATIONS1 DIMENSIONS...........................19” wide X 5 1/4” high (3 RU) MOUNTING..............................Fits standard 19-inch equipment rack. MODULES ................................Provides mounting space for one 1 7/8” wide X 5 1/8” high module, and up to five 3” wide X 5 1/8” high modules. (Spaces may also be combined to accommodate wider modules.) 1 These specifications are intended primarily for the use of the service technician.
PANEL DESCRIPTIONS 2.0 PANEL DESCRIPTIONS The 19D904009G1 through G30 (group 1 through group 30) Enhanced Digital Access Communications System (EDACS) Interface Panels are used as the connection points between cables outside and cables inside an EDACS equipment cabinet. The EDACS Interface Panels are intended to simplify the wiring between EDACS equipment cabinets through the use of standard cables and easily accessible connection points.
SPECIFICATIONS 19D904009G11 Voter Interface Panel - This interface panel provides the connection points for the cabinet containing the Voter at the Main location in a Voted System or at the Control Point location in a Simulcast System. See Assembly Diagram 19D904009, Sheet 11, Part 41 (number in circle). 19D904009G12 Site Controller VAX-DEC (#1) - This interface panel (along with G13) provides the connection points for the Site Controller cabinet to accommodate the VAX computer.
PANEL DESCRIPTIONS 19D904009G23 Auxiliary Receiver Conventional - This interface panel provides the connection points for a cabinet containing conventional MASTR III Auxiliary Receivers. When this interface panel is used in the Voter 95 application, see LBI-39075. See Assembly Diagram 19D904009, Sheet 23, Part 53 (number in circle).
PANEL DESCRIPTIONS Table 1 – Module Makeup of EDACS Interface Panels by Group Number INTERFACE MODULE DRAWING NO.
MODULE DESCRIPTIONS 3.0 MODULE DESCRIPTIONS The following descriptions for each interface module give the application and a reference to the applicable instruction manual: 19C852204G1 Interface Module - This is a general-purpose interface module that connects four wires from each of ten six-pin modular connectors (for inside connections) to two fifty-pin Telco connectors (for outside connections). See LBI-38813.
MODULE DESCRIPTIONS 19C852447G1 Serial Interface Module - This module replaces the earlier 19C852323G1 Serial Interface Module and adds connection points for the GETC reset and status lines (used by Guardog) to the previously provided connection points for the Failsoft and RIC data links. See LBI-39136.
PARTS LIST 4.
STATION ASSEMBLY DIAGRAM 5.0 STATION ASSEMBLY DIAGRAMS: EDACS INTERFACE PANEL (G1) – STATION ASSEMBLY (19D904009, Sh. 1, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G2) - CTIS MAIN COMPUTER CABINET (19D904009, Sh. 2, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G3) – CTIS RIC CABINET (Part of 19D904009, Sh. 3, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G4) – SIMULCAST STATION (19D904009, Sh. 4, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G5) – SIMULCAST TX COMMON EQUIPMENT (19D904009, Sh. 5, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G6) – SITE CONTROLLER-PDP11 (Part of 19D904009, Sh. 6, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G7) – AUXILIARY RECEIVER – MODEM (19D904009, Sh. 7, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G8) – EURO EDACS ASSEMBLY (19D904009, Sh. 8, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G9) – GETC SIMULCAST CONTROL POINT (1-12) (19D904009, Sh. 9, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G10) – GETC SIMULCAST CONTROL POINT (13-20) (19D904009, Sh. 10, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G11) – VOTER INTERFACE PANEL (19D904009, Sh. 11, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G12) – SITE CONTROLLER VAX-DEC (#1) (19D904009, Sh. 12, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G13) – SITE CONTROLLER VAX-DEC (#2) (19D904009, Sh. 13, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G14) – CTIS MAIN COMPUTER VAX-DEC (19D904009, Sh. 14, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G15) – SIMULCAST CONTROL POINT (19D904009, Sh. 15, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G16) – EURO EDACS LEASED LINE INTERFACE (10D904009, Sh. 16, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G17) – RIC TRANSFORMER PANEL (19D904009, Sh. 17, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G18) – JESSICA CONTROL 19D904009, Sh. 18, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G19) – DVIU INTERFACE PANEL (19D904009, Sh. 19, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G20) – STN VOTER INTERFACE (19D904009, Sh. 20, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G21) – VOTER RIC INTERFACE 19D904009, Sh. 21, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G22) – AUXILIARY RECEIVER RS-232 (19D904009, Sh. 22, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G23) – AUXILIARY RECEIVER C0ONVENTIONAL (19D904009, Sh. 23, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G25) – SIMULCAST TX STE (RS-232 DATA) (19D904009, Sh. 24, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G26) – SIM INTERFACE PANEL (19D904009, Sh. 25, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G28) – SITE SENTRY/ELI/SIM (MASTR III) (19D904009, Sh. 26, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G29) – PRISM SITE SENTRY/SIM (19D904009, Sh. 27, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G30) – PRISM ELI AUDIO (19D904009, Sh. 28, Rev.
STATION ASSEMBLY DIAGRAM EDACS INTERFACE PANEL (G31 & G32) – STATION ASSEMBLY WITH SITEPRO (19D904009, Sh. 29, Rev.
(This page intentionally left blank) LBI-38812K 41
M/A-COM Wireless Systems 3315 Old Forest Road Lynchburg, Virginia 24501 (Outside USA, 434-385-2400) Toll Free 800-528-7711 www.macom-wireless.com Printed in U.S.A.