MODULE DESCRIPTIONS
10 LBI-38812K
19C852447G1 Serial Interface Module - This module replaces the earlier
19C852323G1 Serial Interface Module and adds connection points for the GETC reset
and status lines (used by Guardog) to the previously provided connection points for the
Failsoft and RIC data links. See LBI-39136.
19C852632G1 Power Sensor Interface Module - This module provides the connection
points for transmitter and antenna power sensor circuits at the Site Controller cabinet
when using the new DB8860-based Power Monitor Unit. This module is added to (but is
not a part of) the EDACS Interface Panel in the Site Controller cabinet when the new
DB8860-based Power Monitor Unit is added. This module also comes with two plug-in
19C852379G1 Power Sensor Termination Boards. See LBI-39137.
19D904678G1 RIC-Voter Interface Board - This module provides the connection
points between the Voter Analog Cross Connect Panel, Analog Processing Shelf, and
RIC Shelves at the Main Site of a Voted System (or the Control Point of a Simulcast
System) with IDA Local Telephone Interconnect. See LBI-39022.
19D904833G1 STN-Voter Interface Board - This module provides the connection
points between the Modem Shelves and the Voter Analog Cross Connect Panel (or the
Voter Selector GETC when using Digital Dispatch) at the Main Site of a Voted System
(or the Control Point of a Simulcast System). See LBI-39021.
188D5120G1 Microwave Distribution Panel - This module provides the connection
points and cross connects to group all of low-speed data circuits on one connector, all
alarm circuits on a second connector, and all sync tone circuits on a third connector,
from ten other connectors connected to separate Microwave Cross Connect Panels at the
Control Point of a Simulcast System.
ROA1172209 Timing Interface Module (RS-232 Version) - This module provides the
cross connects for the clock reference circuits between the Transmit (or Control Point)
Cross Connect, Universal Sync Shelf, and Multiplex Cross Connect (or Timing
Concentrator) at the Transmit (or Control Point) site of a Simulcast System. See
Maintenance Manual LBI-39099.
ROA1172410/1 UAS/ELI/SIM – This module provides the connection points between
the power sensor circuits in the system and the Universal Alarm system. See
Maintenance Manual EN/LZB 119 3775/1.
ROA1172485/1 PRISM ELI AUDIO – This module provides the connection points in a
Prism MASTR system for the Tx audio and Intercom audio from each channel to its
appropriate ELI shelf. See Maintenance Manual AE/LZB 119 4601/1.