Overview Manual MM-015039-001 Rev.
MM-015039-001, Rev. E MANUAL REVISION HISTORY REV DATE REASON FOR CHANGE B Jul/10 Updated LED indicator tables and graphics. Added equipment weights, dimensions, and VIDA secure Information Assurance information. C Mar/11 Updated product specifications. D Jun/11 Updated VHF regulatory and product information. E Sep/12 Added new DC distribution panels (EA-555019-003 and EA-555019-004), P25 Phase 2 information, and regulatory information for UHF band.
MM-015039-001, Rev. E TABLE OF CONTENTS Section Page 1 REGULATORY AND SAFETY INFORMATION ...................................................................................... 5 1.1 SAFETY SYMBOL CONVENTIONS .................................................................................................. 5 1.2 IMPORTANT SAFETY INSTRUCTIONS ........................................................................................... 5 1.3 MAXIMUM PERMISSIBLE EXPOSURE LIMITS ................................
MM-015039-001, Rev. E TABLE OF CONTENTS Section Page FIGURES Figure 3-1: MASTR V Multi-Channel Base Station Shelf Equipped with One (1) RF Channel.............................. 12 Figure 4-1: MASTR V MHz Base Station Shelf equipped with Four (4) RF Channels ........................................... 13 Figure 4-2: 14-Slot Base Station Shelf .....................................................................................................................
MM-015039-001, Rev. E 1 REGULATORY AND SAFETY INFORMATION 1.1 SAFETY SYMBOL CONVENTIONS The following conventions are used throughout this manual to alert the user to general safety precautions that must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere violates safety standards of design, manufacture, and intended use of the product.
MM-015039-001, Rev. E 1.3 • Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. • Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety.
MM-015039-001, Rev. E WARNING 1.4 Failure to observe these limits may allow all persons within the MPE radius to experience RF radiation absorption, which exceeds the FCC maximum permissible exposure (MPE) limit. It is the responsibility of the base station operator to ensure that the maximum permissible exposure limits are observed at all times during base station transmission. The base station licensee is to ensure that no bystanders are within the radius limits.
MM-015039-001, Rev. E 1.6 REGULATORY APPROVALS 1.6.1 Federal Communications Commission The transmitting device described within this manual has been tested and found to meet the following regulatory requirements: FCC FILING DATA FOR MASTR V BASE STATION FREQUENCY BAND (MHz) POWER OUTPUT (ADJUSTABLE) (Watts) FCC TYPE ACCEPTANCE NUMBER APPLICABLE FCC RULES 470.00625 – 493.99375 10 – 100 OWDTR-0100-E Part 90 494.00625 – 511.
MM-015039-001, Rev. E 1.6.2 Industry Canada INDUSTRY CANADA FILING DATA FOR MASTR V BASE STATION FREQUENCY BAND (MHZ) INDUSTRY CANADA CERTIFICATION NUMBER APPLICABLE INDUSTRY CANADA RULES 470.00625 – 493.99375 3636B-0100 RSS-119 494.00625 – 511.99375 3636B-0101 RSS-119 764 – 776 3636B-0057 RSS-119 851 – 869 3636B-0053 RSS-119 150 – 174 3636B-0065 RSS-119 This Class A digital apparatus complies with Canadian ICES-003.
MM-015039-001, Rev. E 2 SPECIFICATIONS General Specifications 1 Duty Cycle (EIA) Continuous: Transmit and Receive at 100% Operating Temperature: -22°F to +140°F (-30°C to +60°C) Humidity (EIA): 90% at 122°F (50°C) Non-condensing AC Power Supply: Input Power Source: 90 – 240 VAC (nominal), 47~63 Hz Source Power Drain: 1000 watts per channel (max.) @ 120 VAC 600 watts per channel (typical) @ 120 VAC Input Power Efficiency: > 85% at full load (120 VAC) > 82.
MM-015039-001, Rev.
MM-015039-001, Rev. E 3 INTRODUCTION The MASTR V Base Station is a P25 Phase 2 capable transceiver. The station is fully upgradable to P25 Phase II. The MASTR V Base Station is a digital, IP based, LMR communications base station operating within a compact shelf design. It supports IP-based remote software uploads and configuration. IP-based programming may be accomplished using the VIDA Device Manager programming tool.
MM-015039-001, Rev. E 4 MASTR V BASE STATION OVERVIEW 4.1 MULTI-CHANNEL BASE STATION SHELF ASSEMBLY The MASTR V multi-channel base station shelf assembly is a unified sub-rack design providing 14 identical vertical module slots. Also included are two (2) horizontal slots located under the 14 vertical slots, and used to connect the built-in main and redundant Ethernet Switch modules.
MM-015039-001, Rev. E 4.1.1 Multi-Channel Base Station Shelf The MASTR V Multi-channel Base Station shelf model EA-555002-001 is a 14-slot, 5-RU, shelf assembly. The shelf provides a modular environment supporting almost any combination of MASTR V modules. Assembled to the rear of the shelf is a unified backplane assembly. The backplane interfaces all data, frequency reference, and DC power connections from the 14 module slots, to the two (2) horizontally positioned Ethernet switch modules.
MM-015039-001, Rev. E 4.2 HIGH POWER AMPLIFIER/POWER SUPPLY SHELF ASSEMBLY The High Power Amplifier (HPA) (refer to Section 4.3.6) and the Power Supply (PS) (refer to Section 4.3.6.1) are installed in a 19” rack mountable, 2-slot metal shelf, model MA-555003 (refer to Figure 4-3). The HPA/PS shelf is a mechanical-only assembly with no electrical components. Figure 4-3: MASTR V HPA/PS Shelf Assembly (Shown with HPA and PS Installed) 4.
MM-015039-001, Rev. E Table 4-3: Ethernet Switch – Front Panel Indicators and Controls INDICATOR/CONTROL Status LED Reset Switch INDICATOR COLOR DESCRIPTION OFF No Status (Power OFF) GREEN SOLID Active Switch GREEN FLASHING Standby Switch RED SOLID Major Fault RED FLASHING Minor Fault YELLOW SOLID Flash Write YELLOW FLASHING Program Downloading N/A Soft Module Reset Figure 4-4: Ethernet Switch Module 4.3.
MM-015039-001, Rev. E Figure 4-5: TX Module All electrical connections used during normal operation are located on the rear panel (refer to Figure 4-5). Control, data, small signal, and DC power connections mate with the unified backplane. A low level TX exciter output connector is located on the rear panel.
MM-015039-001, Rev.
MM-015039-001, Rev. E Figure 4-6: RX Module Table 4-6: RX Module Connections LOCATION CONNECTOR Rear Panel Circuit Board (side) DESCRIPTION SMA Receiver Antenna Input 3.
MM-015039-001, Rev. E 4.3.3.1 Front End Preselector Each VHF and UHF MASTR V receiver is equipped with an external RF Front End Preselector, model EA-555018-xxx. The preselector (refer to Figure 4-7) for each receiver module is mounted to a frame assembly located on the rear rack rails near each MASTR V shelf. The preselectors provide narrow bandpass filtering to meet the channel spacing typically used in the VHF and UHF bands. Figure 4-7: RF Front End Preselector 4.3.
MM-015039-001, Rev.
MM-015039-001, Rev.
MM-015039-001, Rev. E The TC module manages data and control information for one (1) TX and one (1) RX channel module. Incoming data from dispatch points is processed into over-the-air P25-formatted TX messages. The TC module processes decoded radio information received from the BBP module, and handles all aspects of trunking (subscriber unit validation, assigned channels, queuing, etc.). During P25 operation, the TC module interprets and directs inbound calls.
MM-015039-001, Rev. E Figure 4-9: Traffic Controller Module 4.3.6 High Power RF Power Amplifier Module (HPA) The RF High Power Amplifier (HPA) assembly EA-555014 (shown in Figure 4-10), amplifies the exciter output to the rated station output power level. This module contains a power module, amplifier drivers and power control circuitry required for power amplification The Power Amplifier assembly is a continuous duty, solid state, wide-band RF power amplifier.
MM-015039-001, Rev.
MM-015039-001, Rev.
MM-015039-001, Rev. E Table 4-14: PS Front Panel Indicators and Switches INDICATOR/CONTROL +28 VDC LED +12 VDC LED +5 VDC LED AC Power LED ON/OFF Switch INDICATOR COLOR DESCRIPTION Off OFF or not operational Green Solid Operational Off OFF or not operational Green Solid Operational Off OFF or not operational Green Solid Operational Off OFF or not operational Green Solid Operational N/A AC Power ON/OFF 4.3.
MM-015039-001, Rev. E rear rails required to mount multiple power strips and distributes the load across multiple circuits which minimizes the number of hardware devices which fail when circuit protections trips.
MM-015039-001, Rev. E Recent DC-powered MASTR V sites use the enhanced DC Power Distribution Blocks, models EA555019-003 (Low Power) and EA-555019-004 (High Power). Similar in function to the DC Power Distribution blocks shown above, the enhanced versions include connector assemblies for the DC input connections. The addition of DC input connectors provide ease of installation and improves performance of the MASTR V DC distribution.
MM-015039-001, Rev. E 4.4 RACK AND CABINET ASSEMBLIES This MASTR V base station configuration is available in an extra deep 86-inch x 46-RU open rack, part number BAT 150 196/22 (refer to Figure 4-17), or an extra deep 86-inch x 45-RU cabinet, part number MA-555025 series (refer to Figure 4-17). Both models support installation of 19-inch rack mountable equipment. Figure 4-17: 86-inch Open Rack Assembly Figure 4-18: 86-inch Extra Deep Cabinet 4.4.
MM-015039-001, Rev. C 5 PROGRAMMING, TEST, AND DIAGNOSTICS 5.1 VIDA DEVICE MANAGER Setup, configuration, and programming of a MASTR V P25 Trunked base station is accomplished through the use of the VIDA Device Manager programming software tool. VIDA Device Manager is an easy-to-use programming tool designed around a Windows-based file management system that permits users to configure and manage devices within their system. The user can save/open personalities using the Windows file system.
MM-015039-001, Rev.
MM-015039-001, Rev. E 7 CUSTOMER SERVICE 7.1 TECHNICAL SUPPORT The Technical Assistance Center's (TAC) resources are available to help with overall system operation, maintenance, upgrades and product support. TAC is the point of contact when answers are needed to technical questions. Product specialists, with detailed knowledge of product operation, maintenance and repair provide technical support via a toll-free (in North America) telephone number.
MM-015039-001, Rev. E This page intentionally left blank.
MM-015039-001, Rev. E WARRANTY A. Harris Corporation, a Delaware Corporation, through its RF Communications Division (hereinafter "Seller") warrants to the original purchaser for use (hereinafter "Buyer") that Equipment manufactured by or for the Seller shall be free from defects in material and workmanship, and shall conform to its published specifications. With respect to all non-Seller Equipment, Seller gives no warranty, and only the warranty, if any, given by the manufacturer shall apply.
Public Safety and Professional Communications | www.pspc.harris.