7 SUBSCRIBER STATION CONNECTIONS
7.1 POWER CONNECTIONS
Power is supplied to the client through a 2-pin connector. A #12-16 Socket Multi-Con-X mating
connector kit, CN-014934 is supplied with the unit. A pre-made 2/12 AWG Power Cable assembly, CA-
014984-XXXXX or CA-014988-XXXXX, is available in various lengths. Refer to the VIDA Broadband
Installation Manual, MM-014720-001 for details.
7.1.1 Subscriber Station DC Connections
Table 7-1: Client DC Power Connector
CONNECTION PIN POWER CONNECTOR
PWR+ (+11 to +30 Vdc) 1
1
2
PWR-
(Return)
PWR+
(11-30 Vdc)
PWR- (Return) 2
7.1.2 Subscriber Station AC Connections
T he A C supply must be isolated fr om AC mains; the use of an isolating step-down
transfor mer is necessar y. T he AC supply must not have a ground path; gr ound
should be supplied through a separ ate wir e to the grounding stud. F ailur e to
obser ve this warning may r esult in electrical shock or damage to equipment.
Table 7-2: Client AC Power Connector
CONNECTION PIN CLIENT AC POWER CONNECTOR
HOT (16 to 26 Vac) 1
Hot (16-26 Vac)
Neutral
1
2