REPORT NO : HCT-F04-1004 FCC ID : O5XHP-500B DATE : OCTOBER 18, 2004 ATTACHMENT E-1. - USER’S MANUAL(1) HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI , BUBAL-EUP, ICHEON-SI,KYOUNKI-DO, 467-701,KOREA TEL : +82 31 639 8518 FAX : +82 31 639 8525 www.hctec.co.
U.S .A . U.S .F E DE RA L C OMMUNIC A T IONS C OMMIS S ION RA DIO F RE QUE NC Y INT E RF E RE NC E S T A T E ME NT INF ORMA T ION T O T HE US E R NOT E : T his equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the F CC R ules. T hese limits are designed to provide reasonable protection against harmful Interference in a residential installation.
Contents Important Safety Information ................................................................................................................ 2 Overview of Your New PDP .................................................................................................................... 8 OSD key Position .............................................................................................................................................. 8 OSD key function ....................................
Important Safety Information CAUTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK), NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Important Safety Information Always be careful when using your PDP. To reduce the risk of fire, electrical shock, and other injuries, keep these safety precautions in mind when installing, using, and maintaining your machine. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any of the ventilation openings.
Important Safety Information Follow all operating and use instructions. Unplug the Monitor from the wall outlet before cleaning. Use a damp cloth; do not use liquid or aerosol cleaners. Do not use the Monitor where contact with or immersion in water is a possibility, such as near bath tubs, sinks, washing machines, swimming pools, etc. This plasma display is designed to be mounted horizontally (wide viewing). Any inquiry regarding its vertical position should be forwarded to the manufacture directly.
Important Safety Information Provide ventilation for the Monitor. The unit is designed with slots in the cabinet for ventilation to protect it from overheating. Do not block these openings with any object, and do not place the Monitor on a bed, sofa, rug or other similar surface. Do not place it near a radiator or heat register. If you place the Monitor on a rack or bookcase, ensure that there is adequate ventilation and that you've followed the manufacturer's instructions for mounting.
Important Safety Information Do not overload the wall outlet or extension cords. Overloading can result in fire or electric shock. Do not insert anything through the openings in the unit, where they can touch dangerous voltage points or damage parts. Never spill liquid of any kind on the Monitor. Bend antenna cable between inside and outside building to prevent rain from flowing in. - This may cause water damaged inside the Monitor and could give an electric shock. Ground outdoor antennas.
Important Safety Information When replacement parts are required, be sure the service technician uses replacement parts specified by the manufacturer or those that have the same characteristics as the original part. Unauthorized substitutions may result in additional damage to the unit. Upon completion of any service or repairs to this Monitor, ask the service technician to perform safety checks to determine that the Monitor is in a safe operating condition.
Overview Of Your New PDP OSD Key Position Front Panel OSD key & Function 1 2 3 < D Type > 4 5 6 Input Source Select UP DOWN (See the box below.) Power (Stand By) Status / Power Indicator LED Remote Sensor < I Type > OSD Key Function INPUT SELECT Select the signal source from multiple input sources such as TV, AV 1, AV 2, S-Video / AV, Component1, Component2, PC and DVI. VOL / CH To change the CHANNEL, Press button first and change the CHANNEL with , buttons.
Overview Of Your New PDP Back Panel and Jacks < Back panel of the monitor > 1 RS-232C To control from PC. 2 DVI For PC, Set top box. 3 PC Sound PC/DVI Audio Input. 4 D-Sub (PC) For PC, Set top box. 5 Component 1, 2 6 Component Sound 7 Speakers For DVD, Set top box. For Component Audio Input. To connect speakers (2CH, Stereo) 8 AV 1 9 AV 2 10 S-Video 11 AV Output 12 AV 3 For DVD, Set top box, S-VHS. To connect other TV or monitor. For VCR, DVD, Set top box.
Overview Of Your New PDP 1 RS-232C Jack Connects a control signal from a PC. 2 DVI Input Jack Connects a digital video signal from a DVI output jack of PC or Set Top box. 3 PC Sound Connects a sound signal from PC or DVI. 4 RGB PC Input Jack ( D-Sub ) Connects a video signal from a video output jack of PC. Cables connecting the PC vary according to the type of machine, so contact your product dealer.
Accessories Remote Control Handset RF Cable Power Cord Alkaline Batteries Owner's Manual OWNER'S MANUAL 11
Optional Extras Table Stand (Type United) Fixed Wall Mount Bracket 12 OWNER'S MANUAL Table Stand (Type Separated) Side Mount Speaker
Remote Control 1 Power Turn the PDP on and off. 2 Mute Temporarily cut the sound and restore it. 3 Pre.CH Turn to the previous channel or exit OSD. 4 V.Size Choose the Screen Form. 16:9 ➔ Panorama ➔ Zoom1 ➔ Zoom2 ➔ 4:3 5 FAVORITE (FAVOURITE) Tune to your next favorite channel. 6 100 Press to tune the channels over 100. 7 INPUT Display the input source list. 8 Menu / Set Display the main OSD menu. Activate your choice in the OSD menu. 9 Back Return to the previous OSD menu.
Remote Control 2 3 1 4 6 5 7 8 9 10 12 11 13 14 16 15 1 MTS Choose the MTS (Stereo) mode. Each time it is pressed, different mode is selected. Mono ➔ Stereo ➔ SAP • You can select only available modes depending on the source. 2 CH INFO Display the current information about time, screen form, source and MTS mode. 3 PICTURE There are 4 picture modes. Standard ➔ Vivid ➔ Mild ➔ User 4 STILL Temporarily freeze the screen and restore it. 5 SOUND Choose the sound equalizer settings.
Remote Control Loading The Batteries 1 Press on the cover and slide in the direction of the arrow. 2 Load two AAA batteries, taking care that the + and - ends face the correct direction. 3 Close the cover until it clicks.
Monitor Installation The Monitor can be installed in various ways such as Wall Mounting type, Table Stand type, etc.. Wall Mount Installation (optional) < The monitor can be installed on the wall as the picture above > • Install this monitor only in a location where adequate ventilation is available. 1.
Monitor Installation 1 1 1 1. Before installation of monitor, Assemble to the same inch of the PDP shown as left(2). 2. Lift the monitor brackets off the mounting frame shown as arrow 1. GUIDE BRACKET MONITOR BRACKET WALL MOUNTING BRACKET 2 2 1. Drill the 8 hole positions shown as left. Using an 8mm drill appropriate for the material on the wall, drill each hole to a depth of exceed 80mm. 2. Clean each drill hole. 3. Insert an anchor supplied with the wall mounting bracket into each hole. 4.