Information

01
.
13
SEK · D-Sub
9 09 18 009 70
10 09 18 010 70
14 09 18 014 70
15 09 18 015 70
16 09 18 016 70
20 09 18 020 70
25 09 18 025 70
26 09 18 026 70
34 09 18 034 70
37 09 18 037 70
40 09 18 040 70
50 09 18 050 70
60 09 18 060 70 *
64 09 18 064 70
9 09 18 009 70
10 09 18 010 70
14 09 18 014 70
15 09 18 015 70
16 09 18 016 70
20 09 18 020 70
25 09 18 025 70
26 09 18 026 70
34 09 18 034 70
37 09 18 037 70
40 09 18 040 70
50 09 18 050 70
60 09 18 060 70 *
64 09 18 064 70
Cables for insulation displacement termination
* Not normally kept in stock
Important: always store reals vertically
No. of
Identification contacts Part No. Drawing Dimensions in mm
Round flat cable
with screening
(shielding)
UL listed PLCC CL2
CSA certified AWM FT-1
Length per reel
30.48 m
(100 feet) 07
100 m 10 *
(328 feet)
without screening
(shielding)
UL listed PLCC CL2
CSA certified AWM FT-1
Length per reel
30.48 m
(100 feet) 08
100 m 11 *
(328 feet)
Flat cable, AWG 28/7
Clear polyester
Outer jacket: black PVC
No. of contacts a b c
9 to 26 19.05 19.05 38.10
34 to 64 38.10 19.05 57.15
Flat cable, AWG 28/7
Aluminium / Polyester tape (spiral wrap)
85 % minimum coverage tinned copper braid
Outer jacket: black PVC
Edge mark on
first conductor
AWG 28/7 grey
Slit section
Slit section
6.35
6.35
6.60
6.86
7.11
7.62
8.38
8.38
9.40
9.65
10.16
11.43
12.45
12.70
ø max.
6.86
6.86
7.37
7.62
7.87
8.38
9.14
9.14
10.16
10.41
10.92
12.19
13.21
13.46
Conductor material _________________ Copper tinned
Gauge ___________________________ AWG 28/7 0.089 mm²
Voltage rating ______________________ 300 V
r.m.s.
Conductor resistance ________________ 225 m/m
Capacity unbalanced ________________ 78.7 pF/m
Impedance unbalanced ______________ 75
Signal delay _______________________ 5.25 ns/m nom.
Insulation material __________________ PVC
Temperature rating _________________ –20 °C … + 105 °C
Flammability rating _________________ UL: VW 1
Insulation resistance ________________ 10
4
M/km