Product Overview

1 & 2 Pole Contactor 20–40 FLA
HCC Series
1 & 2 pole contactors are typically used in residential applications.
These contactors utilize one wire to control electrical current
direction. Our engineers and quality specialists provide services
that meet or exceed customer requirements—all products
undergo in-house testing and validation. We carry extensive
domestic inventory to meet delivery schedules.
Features
1 Pole NO with or without shunt
2 Pole NO
Silver Cadmium Oxide Contacts
UL 508 File No. E227250
Semko/CE File No. EN 60947-4-1:2001
CSA File No. 221260 (1456104)
Multiple mounting and termination options available,
contact us for more information.
CONTACTORS
Initial Dielectric Strength
Between Contacts & Coils: 2,200 VAC
Between Poles: 2,200 VAC (includes shunt)
Between Open Contacts: 2,200 VAC (no shunt)
Arc Cover
Optional on 20–30 FLA
Standard on 40 FLA
Insulation System
130°C Class B
Temperature Range
-40°C to +65°C
-40°F to +150°F
Unit Weight
1 Pole 8 oz
2 Pole 9.6 oz
Power Pole Terminations
#10-32 screw or box lug
Wire Size
#10-32 screw 16-8 (#8 must use ring terminal)
Box lug 14-4
Recommended Tightening Torque
#10-32 screw: 22 in. lbs
Box lug: 40 in. lbs
Quick Connects
Coil terminals:
Dual: .250″ QC
Power terminals:
1 Pole: Dual or Quad .250″ QC
2 Pole: Dual or Quad .250″ QC
We can custom engineer a solution
to meet any need. Just ask.
815.626.5170 | HartlandControls.com