8 and 13" DIS DDC Control sssssss DOC101681-1- rev.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS Revision History Created Approved Rev Date By Date By Description 01 2013-10-25 André Kråkenes 2013-10-28 Wei Jing Based on SDS-002-000-02 2 2013-11-06 André Kråkenes 2013-11-06 Wei Jing Removed reference to custom models.
8 and 13" DIS DDC Control sssssss All intellectual properties belongs to Hatteland Display AS DOC101681-1- rev.2 Index of page 1. General Description ............................................................................................................... 4 2. Block Diagram ........................................................................................................................ 4 Monitor Inside Block Connect .........................................................................
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 1. General Description Support standard DDC/CI format communicate. The maximum transfer rate is 100 kb/s in “standard-mode”. Support Manufacturer Specific DDC/CI format communicates. Support ALARM Board Control 2.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS 3. Communicate List Define an I2C™ based protocol which operates over the DDC channel to provide interactive control of a display and, optional associated devices. Communicate are divided into two parts. One is the standard and other is a manufacture specific. 3.1.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS 6F Destination address 6E Source address 88 Length 02 VCP Feature reply op code RC Result Code 00h: No Error 01h: Unsupported VCP Code CP VCP opcode from Feature request message TP VCP type code 00h: Set parameter 01h: Momentary MH Maximum value High byte ML Maximum value Low byte SH Present value High byte SL Present value Low byte CK DDC/CI checksum 3.2.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 3.2.1. VCP Code: 0x03 Soft Controls Allows display controls to be used as soft keys.
and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 [S] 6E [W] 51 82 01 12 AE [P] [S] 6F [R] 6E 88 02 00 12 00 00 64 00 59 9B [P] Green color VCP opcode Blue color High byte / Low byte 3.2.5. VCP Code: 0x13 Back Light Control Increasing (decreasing) this value in the second byte will increase (decrease) the specified Backlight Control value.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 Command example: [S] 6E [W] 51 84 03 1E 00 01 A7 [P] Green color VCP opcode Blue color High byte / Low byte 3.2.8.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 [S] 6E [W] 51 84 03 C0 00 00 78 [P] Complete instructions, [S] 6E [W] 51 84 03 04 A0 01 1D [P] Into factory mode. [S] 6E [W] 51 84 03 C0 00 00 78 [P] Setting display usage time to zero. [S] 6E [W] 51 84 03 04 A0 00 1C [P] Leave factory mode. 3.2.10.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS [S] 6F [R] 6E 88 02 00 CC 00 00 0A 00 02 70 [P] Green color VCP opcode Blue color High byte / Low byte Data setting description 02h: English 03h: French 04h: German 05h: Italian 06h: Japanese 10h: Spanish 3.2.12. VCP Code: 0xDF VCP Version Define the version number of VCP list recognized by the display.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS 0x0703 HTD0850CI-DTC 8" DIS TCP 0x0706 HTD1350CI-DTC 13.3” DIS TCP 0x070D HTD0850CI-HD0 / HTD0850CI-DTC(HD) 8" DIS TCP(HD) 0x070E HTD1350CI-HD0 / HTD1320CI-DTC(HD) 13.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS 3.3. DDC/CI Manufacture Specific Command ( 0xF3 Watchdog Function ) VCP Code value is 0xF3 that it is watchdog function control to bridge of DDC/CI communication. That it is follow table read and write format with DDC/CI data communication. Format is as below.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 [S] 6F [R] 6E 90 E4 0D 00 31 30 30 39 30 39 52 30 56 30 31 0A 00 79 [P] Red color Get data length Green color Sub function ID Blue color WD firmware data and end char. Return string is “100909R0V01”. 3.3.2. Sub-Function: 0x01 Watchdog mode name Data array is ASCII char string return and 0x0A is end.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS Watchdog board DIS identity table: ID Model 0x0700 Description (Firmware Model Name string) Reserve 0x0701 HTD0850CI-DKM 8" DIS Customized Model 0x0702 HTD1350CI-DKM 13.3" DIS Customized Model 0x0703 HTD0850CI-DTC 8" DIS TCP 0x0706 HTD1350CI-DTC 13.3” DIS TCP 0x070D HTD0850CI-HD0 8" DIS TCP(HD) 0x070E HTD1350CI-HD0 / HTD1320CI-DTC(HD) 13.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS [S] 6F [R] 6E 84 E4 01 11 C8 86 [P] Red color Set or Get data length. Green color Sub function ID. Blue color Set or get data. 3.3.6. Sub-Function: 0x15 Back Light PWM output value setting. This command is PWM output value control direct to back light that value range is 0 to 60000.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 This command is watchdog active to wait time. Command example: [S] 6E [W] 51 86 E7 F3 02 21 01 F4 7B [P] [S] 6E [W] 51 84 E2 F3 02 21 89 [P] [S] 6F [R] 6E 85 E4 02 21 01 F4 89 [P]] Red color Set or Get data length. Green color Sub function ID. Blue color Set or get data. 3.3.9.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 Command example: [S] 6E [W] 51 84 E7 F3 00 26 89 [P] Red color set data length. Green color Sub function ID. 3.3.13. Sub-Function: 0x27 ALARM ACK This command is buzzer OFF and error LED dark when watchdog is active to fault. Command example: [S] 6E [W] 51 84 E7 F3 00 27 88 [P] Red color set data length. Green color Sub function ID. 3.3.14.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS Touch Pad LED Display DN VCP Code Sub-F 0xF3 0x30 d1) Pad LED ON/OFF 1 1 RW 0xF3 0x31 d2) Pad LED Dimming Control 1 1 RW 0xF3 0x32 d3) Pad LED Dimming Control Adjust follow Back Light 1 1 RW Function Description R W Type 3.3.15. Sub-Function: 0x30 Pad LED ON/OFF This command is turn it ON or OFF to pad LED.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS [S] 6E [W] 51 85 E7 F3 01 32 01 9C [P] [S] 6E [W] 51 84 E2 F3 01 32 99 [P] [S] 6F [R] 6E 84 E4 01 32 01 6C [P] Red color Set or Get data length. Green color Sub function ID. Blue color Set or get data. Data setting description 0x00 Independent controls. 0x01 Follow back light control.
8 and 13" DIS DDC Control sssssss DOC101681-1- rev.2 All intellectual properties belongs to Hatteland Display AS [S] 6E [W] 51 84 E2 F3 01 39 92 [P] [S] 6F [R] 6E 84 E4 01 39 03 65 [P] Red color Set or Get data length. Green color Sub function ID. Blue color Set or get data. Data setting description When value is 0 that sensor reaction level is range 1. When value is 1 that sensor reaction level is range 2. When value is 2 that sensor reaction level is range 3.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 Red color set data length. Green color Sub function ID. 0x41 [S] 6E [W] 51 84 E7 F3 00 41 EE [P] Red color set data length. Green color Sub function ID. 0x42 [S] 6E [W] 51 84 E7 F3 00 42 ED [P] Red color set data length. Green color Sub function ID. 0x43 [S] 6E [W] 51 84 E7 F3 00 43 EC [P] Red color set data length.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 Red color set data length. Green color Sub function ID. 0x49 [S] 6E [W] 51 84 E7 F3 00 49 E6 [P] Red color set data length. Green color Sub function ID. 0x4A [S] 6E [W] 51 84 E7 F3 00 4A E5 [P] Red color set data length. Green color Sub function ID. 0x4B [S] 6E [W] 51 84 E7 F3 00 4B E4 [P] Red color set data length.
8 and 13" DIS DDC Control All intellectual properties belongs to Hatteland Display AS sssssss DOC101681-1- rev.2 4. Implementation The easiest/quickest way to implement control of the DDC in a Windows environment application is to use a library designed for this task. An example of such a library is the WinI2C-DDC. “WinI2C/DDC is a professional tool that allows you to control display devices in the Windows environment via the DDC/CI protocol.