Owner manual

19
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command Syntax and Functionality ACK Details and Values
Manual Phase Control
Note:
Dot clock (for RGB mode only)
Syntax : 07 FF 4D 43 43 03 23 85 xx yy zz
Function Examples:
Example "3F" : 07 FF 4D 43 43 03 23 85 33 46 01
Query "?" : 07 FF 4D 43 43 02 24 85 3F 3B
Reset "R" : 07 FF 4D 43 43 02 24 85 52 28
Reset "r" : 07 FF 4D 43 43 02 24 85 52 08
Increase "+" : 07 FF 4D 43 43 02 24 85 2B 4F
Decrease "-" : 07 FF 4D 43 43 02 24 85 2D 4D
Where xx = "0" to "3"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "3" "F"
Image Horizontal Position
Syntax : 07 FF 4D 43 43 03 23 86 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 86 35 30 14
Query "?" : 07 FF 4D 43 43 02 24 86 3F 3A
Reset "R" : 07 FF 4D 43 43 02 24 86 52 27
Reset "r" : 07 FF 4D 43 43 02 24 86 72 07
Increase "+" : 07 FF 4D 43 43 02 24 86 2B 4E
Decrease "-" : 07 FF 4D 43 43 02 24 86 2D 4C
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
If DVI mode: "?"
Note: If Value > 100 then
Value=100
Image Vertical Position
Syntax : 07 FF 4D 43 43 03 23 87 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 87 35 30 13
Query "?" : 07 FF 4D 43 43 02 24 87 3F 39
Reset "R" : 07 FF 4D 43 43 02 24 87 52 26
Reset "r" : 07 FF 4D 43 43 02 24 87 72 06
Increase "+" : 07 FF 4D 43 43 02 24 87 2B 4D
Decrease "-" : 07 FF 4D 43 43 02 24 87 2D 4B
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
If DVI mode: "?"
Note: If Value > 100 then
Value=100
Sharpness
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23 8A xx yy zz
Function Examples:
Example "07" : 07 FF 4D 43 43 03 23 8A 30 37 0E
Query "?" : 07 FF 4D 43 43 02 24 8A 3F 36
Reset "R" : 07 FF 4D 43 43 02 24 8A 52 23
Reset "r" : 07 FF 4D 43 43 02 24 8A 72 03
Increase "+" : 07 FF 4D 43 43 02 24 8A 2B 4A
Decrease "-" : 07 FF 4D 43 43 02 24 8A 2D 48
Where xx = "0" to "F"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "0" "F"
Default: "0" "7"
Manual Frequency Control
Note:
PC mode only.
Syntax : 07 FF 4D 43 43 05 21 8B vv ww xx yy zz
Function Examples:
Example "0050" : 07 FF 4D 43 43 05 21 8B 30 30 35 30 AF
Query "?" : 07 FF 4D 43 43 02 24 8B 3F 35
Increase "+" : 07 FF 4D 43 43 02 24 8B 2B 49
Decrease "-" : 07 FF 4D 43 43 02 24 8B 2D 47
Where vv = "0" to "0"
Where ww = "0" to "0"
Where xx = "0" to "C"
Where yy = "0" to "E"
Where zz = Calculated Checksum
Max Range:
"0" "0" "0" "0" to "0" "0" "C" "E"
If wrong mode: "?"
Scaling Mode
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 8C xx zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24 8C 32 41
Query "?" : 07 FF 4D 43 43 02 24 8C 3F 34
Reset "R" : 07 FF 4D 43 43 02 24 8C 52 21
Reset "r" : 07 FF 4D 43 43 02 24 8C 72 01
Where xx = "0" to "4"
Where zz = Calculated Checksum
If wrong mode: "?"
Available functions:
"0" = 1:1
"1" = Fill Screen
"2" = Fill to Aspect Ratio
"3" = Anamorphic
"4" = Auto
OSD Horizontal Position
Syntax : 07 FF 4D 43 43 03 23 90 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 90 35 30 0A
Query "?" : 07 FF 4D 43 43 02 24 90 3F 30
Reset "R" : 07 FF 4D 43 43 02 24 90 52 1D
Reset "r" : 07 FF 4D 43 43 02 24 90 72 FD
Increase "+" : 07 FF 4D 43 43 02 24 90 2B 44
Decrease "-" : 07 FF 4D 43 43 02 24 90 2D 42
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
Note: If Value > 100 then
Value=100.
If Value is not multiple by ten, it
change to less nearest multiple
value.