Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command Syntax and Functionality ACK Details and Values
Video System
Syntax : 07 FF 4D 43 43 02 24 9B xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 9B 31 33
Query "?" : 07 FF 4D 43 43 02 24 9B 3F 25
Reset "R" : 07 FF 4D 43 43 02 24 9B 52 12
Reset "r" : 07 FF 4D 43 43 02 24 9B 72 F2
Where xx = "0" to "3"
Where zz = Calculated Checksum
Available functions:
"0" = Auto (Default)
"1" = NTSC
"2" = PAL
"3" = SECAM
Otherwise set to Auto
Gamma Value Select
Syntax : 07 FF 4D 43 43 02 24 9D xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 9D 31 31
Query "?" : 07 FF 4D 43 43 02 24 9D 3F 23
Reset "R" : 07 FF 4D 43 43 02 24 9D 52 10
Reset "r" : 07 FF 4D 43 43 02 24 9D 72 F0
Where xx = "0" to "2"
Where zz = Calculated Checksum
Available functions (MMD):
"0" = 1.0 (Default)
"1" = 1.6
"2" = 2.2
Power Down / DPMS Option
Syntax : 07 FF 4D 43 43 02 24 9F xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 9F 31 2F
Query "?" : 07 FF 4D 43 43 02 24 9F 3F 21
Reset "R" : 07 FF 4D 43 43 02 24 9F 52 0E
Reset "r" : 07 FF 4D 43 43 02 24 9F 72 EE
Where xx = "0" to "1"
Where zz = Calculated Checksum
Available functions:
"0" = Power Off
"1" = Power On
Direct Access
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 A0 xx zz
Function Examples:
Example "6" : 07 FF 4D 43 43 02 24 A0 36 29
Query "?" : 07 FF 4D 43 43 02 24 A0 3F 20
Reset "R" : 07 FF 4D 43 43 02 24 A0 52 0D
Reset "r" : 07 FF 4D 43 43 02 24 A0 72 ED
Where xx = "0" to "8"
Where zz = Calculated Checksum
Available functions:
"0" - Brightness
"1" - PIP size
"2" - Main source
"3" - Second source
"4" - Alpha Blend
"5" - Video Scaling
"6" - Swap
"7" - Test pattern
"8" - No function (default)
Set Runtime Counter
Syntax : 07 FF 4D 43 43 02 24 A1 uu vv ww xx yy zz
Function Examples:
Send "00024": 07 FF 4D 43 43 06 20 A1 30 30 30 32 34 68
Query "?" : 07 FF 4D 43 43 02 24 A1 3F 1F
Where uu = "0" to "9"
Where vv = "0" to "9"
Where ww = "0" to "9"
Where xx = "0" to "9"
Where yy = "0" to "9"
Where zz = Calculated Checksum
Example on Response:
"0" "0" "4" "1" "5" (00415)
Where value is *0.5 hour.
PIP, PBP Brightness Control
Syntax : 07 FF 4D 43 43 03 23 A2 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 A2 35 30 F8
Query "?" : 07 FF 4D 43 43 02 24 A2 3F 1E
Reset "R" : 07 FF 4D 43 43 02 24 A2 52 0B
Reset "r" : 07 FF 4D 43 43 02 24 A2 72 EB
Increase "+" : 07 FF 4D 43 43 02 24 A2 2B 32
Decrease "-" : 07 FF 4D 43 43 02 24 A2 2D 30
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
PIP, PBP Contrast Control
Syntax : 07 FF 4D 43 43 03 23 A3 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 A3 35 30 F7
Query "?" : 07 FF 4D 43 43 02 24 A3 3F 1D
Reset "R" : 07 FF 4D 43 43 02 24 A3 52 0A
Reset "r" : 07 FF 4D 43 43 02 24 A3 72 EA
Increase "+" : 07 FF 4D 43 43 02 24 A3 2B 31
Decrease "-" : 07 FF 4D 43 43 02 24 A3 2D 2F
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"