Owner manual

23
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command Syntax and Functionality ACK Details and Values
Green Level for Selected Color
Temperature
Syntax : 07 FF 4D 43 43 03 23 B5 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 B5 35 30 E5
Query "?" : 07 FF 4D 43 43 02 24 B5 3F 0B
Reset "R" : 07 FF 4D 43 43 02 24 B5 52 F8
Reset "r" : 07 FF 4D 43 43 02 24 B5 72 D8
Increase "+" : 07 FF 4D 43 43 02 24 B5 2B 1F
Decrease "-" : 07 FF 4D 43 43 02 24 B5 2D 1D
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Blue Level for Selected Color
Temperature
Syntax : 07 FF 4D 43 43 03 23 B6 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 B6 35 30 E4
Query "?" : 07 FF 4D 43 43 02 24 B6 3F 0A
Reset "R" : 07 FF 4D 43 43 02 24 B6 52 F7
Reset "r" : 07 FF 4D 43 43 02 24 B6 72 D7
Increase "+" : 07 FF 4D 43 43 02 24 B6 2B 1E
Decrease "-" : 07 FF 4D 43 43 02 24 B6 2D 1C
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Graphic Horizontal Resolution
Query
Note:
VGA Source only
Send Only : 07 FF 4D 43 43 01 25 B7 48
Where zz = Calculated Checksum
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating resolution.
Example:
"0640" = 1600 in decimal
Graphic Vertical Resolution
Query
Note:
VGA Source only
Send Only : 07 FF 4D 43 43 01 25 B8 47
Where zz = Calculated Checksum
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating resolution.
Example:
"0480" = 1200 in decimal
Graphic Horizontal Sync.
Frequency
Note:
VGA Source only
Send Only : 07 FF 4D 43 43 01 25 B9 46
Where zz = Calculated Checksum
Available response status:
"xxx" = where xxx is a 3-digit HEX
number indicating frequency in
units of 100Hz.
Example:
"29F" = 671 or 67.1 kHz decimal
Graphic Vertical Sync.
Frequency
Note:
VGA Source only
Send Only : 07 FF 4D 43 43 01 25 BA 45
Where zz = Calculated Checksum
Available response status:
"xxx" = where xxx is a 3-digit
HEX number indicating frequency
in units of 0.1Hz + 1 character
indicating eld mode as:
"i" = Interlaced
"p" = Progressive
Example:
"256p" = 598 (59.8 Hz),
progressive elds
Auto Setup
Note:
PC mode only.
Send Only : 07 FF 4D 43 43 01 25 C3 3C
Where zz = Calculated Checksum
Available response status:
"0" = Fail
"1" = Successful