Owner manual

24
Serial Communication (SCOM) Interface
Communication Interface
IND100084-12
MCC Command Syntax and Functionality ACK Details and Values
Command Availability Query
Syntax : 07 FF 4D 43 43 03 23 C4 xx yy zz
Function Examples:
Example "C4" : 07 FF 4D 43 43 03 23 C4 43 34 C4
Where xx = "0" to "F"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Example on Response:
"0" = Not available
"1" = Available
Auto Calibration
Note:
Start auto-calibration of gain of
the RGB amplier.
Send Only : 07 FF 4D 43 43 01 25 C5 3A
Available response status:
"0" = Fail
"1" = Successful
Soft Power On/Off
Syntax : 07 FF 4D 43 43 02 24 C8 xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 C8 31 06
Query "?" : 07 FF 4D 43 43 02 24 C8 3F FB
Where xx = "0" to "1"
Where zz = Calculated Checksum
Available functions:
"0" = Soft Power Off
"1" = Soft Power On
Query EVX Firmware Version
Send Only : 07 FF 4D 43 43 02 24 CB 30 04
Available response status:
Version "VV.YY.ZZ?"
VV = V0 or E0
V0 = Release version
E0 = Engineering Sample
YY = Version Number
ZZ = Customer Number
? = For E0 version (A-Z)
Test Pattern
Syntax : 07 FF 4D 43 43 02 24 CD xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 CD 31 01
Where xx = "0" to "1"
Where zz = Calculated Checksum
Available functions:
"0" = Normal Display
"1" = Display built-in Test Pattern
Reset Factory Default
Send Only : 07 FF 4D 43 43 01 25 CE 31
Available response status:
"0" = fail
"1" = successful
Save User Default
Send Only : 07 FF 4D 43 43 01 25 D7 28
Available response status:
"1" = successful
Load User Default
Send Only : 07 FF 4D 43 43 01 25 D8 27
Available response status:
"1" = successful
Wide Screen Mode Selection
Syntax : 07 FF 4D 43 43 02 24 D9 xx zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24 D9 32 F4
Query "?" : 07 FF 4D 43 43 02 24 D9 3F E7
Reset "R" : 07 FF 4D 43 43 02 24 D9 52 D4
Reset "r" : 07 FF 4D 43 43 02 24 D9 72 B4
Where xx = "1" to "2"
Where zz = Calculated Checksum
Available functions:
"1" = 1280x768
"2" = 1366x768
If wrong instruction: "?"
Setup DDC
Send Only : 07 FF 4D 43 43 01 25 DC 23
Available response status:
"1" = successful
Setup Serial Mode
Syntax : 07 FF 4D 43 43 03 24 DB xx yy zz
Function Examples:
Example "A2" : 07 FF 4D 43 43 03 24 DB 41 32 B1
Query "?" : 07 FF 4D 43 43 02 24 DB 3F E5
Where xx = "0" to "F"
Where yy = "1" to "3"
Where zz = Calculated Checksum
Available functions (xx):
xx = Serial Address 0-15 number
Available functions (yy):
"1" - RS-232
"2" - 2-wire RS-485
"3" - 4-wire RS-485 / RS-422
Swap Main & PIP/PBP Source
Note:
Not available on STD units.
Send Only : 07 FF 4D 43 43 01 25 E3 1C
Available response status:
"0" = Fail
"1" = Successful
Read Temperature Sensor
Send Only : 07 FF 4D 43 43 01 25 E4 1B
Available response status:
"xx" = where xx is 2-digit
temperature value in Celcius
Degrees