Manual

21
IND100078-17
General Installation Recommendations
Installation
6. When a product is being installed, the surface base or bulkhead must be checked to ensure that it is at in order to
avoid twisting of the unit when the xing screws are tightened, because such twisting would impair mechanical
functions. Any unevenness should be compensated for by means of spacing-washers.
7. This Product shall be grounded to protective Earth. For AC Power cables this is done trough the ground wire in the
connector, for DC input the ground bolt shall be used. A shorter and thicker cable gives better grounding. A 6mm²
is Recommended, but a 4mm² or even 2.5mm² can be used for this purpose.
8. Transportation damage, even if apparently insignicant at rst glance, must immediately be examined and be
reported to the freight carrier. The moment of setting-to-work of the equipment is too late, not only for reporting the
damage but also for the supply of replacements.
9. The classication is only valid for approved mounting brackets provided by Hatteland Display. The unit shall be
mounted stand-alone without any devices or loose parts placed at or nearby the unit. Any other type of mounting
might require test and re-classication.
Brightness knob precaution
Applies for models with potmeter knob. Please be aware of the risk of breaking or bending the brightness knob. The
brightness knob should be free of any obstruction.
Ergonomics
1. Adjust the unit height so that the top of the screen is at or below eye level. Your eyes should look slightly
downwards when viewing the middle of the screen.
2. Adjust screen inclination to remain gaze angle to the centre of the screen approximately perpendicular to the line
of gaze.
3. When products are to be operated both from a sitting position and from a standing position, a screen inclination of
about 30° to 40° (from a vertical plane) has turned out to be favourable.
4. The brightness of displays is limited. Sunlight passing directly through the bridge windows - or its reection - which
falls upon the screen workplaces must be reduced by suitable means (negatively inclined window surfaces,
benetian blinds, distance from the windows, dark colouring of the deckhead). However, Series 1 can be offered
with optical enhanced technology to reduce reections and are viewable in direct sun light, but as a general rule
the units at the bridge wing area is recommended to be installed or mounted by suitable alignment or bulkhead /
deckhead mounting in such a way that reections of light from the front pane of the display are not directed
into the observer’s viewing direction.
5. The use of ordinary commercial lter plates or lter lms is not permitted for items of equipment that require
approval (by optical effects, “aids” of that kind can suppress small radar targets, for example).
6. For ECDIS applications, the minimum recommended viewing distance are as follows:
(IEC62288, Part 7.5 Screen resolution)
19 inch = 1011mm 20 inch = 878mm 22 inch = 1011mm 23 inch = 1011mm