Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command Syntax and Functionality Details and Values
Scaling Mode
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 8C xx zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24 8C 32 41
Query "?" : 07 FF 4D 43 43 02 24 8C 3F 34
Reset "R" : 07 FF 4D 43 43 02 24 8C 52 21
Reset "r" : 07 FF 4D 43 43 02 24 8C 72 01
Where xx = "0" to "2"
Where zz = Calculated Checksum
Available functions:
"0" = Full (default)
"1" = 1:1
"2" = Fill to aspect ratio
OSD Lock Mode
Syntax : 07 FF 4D 43 43 02 24 8D xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 8D 31 41
Query "?" : 07 FF 4D 43 43 02 24 8D 3F 33
Reset "R" : 07 FF 4D 43 43 02 24 8D 52 20
Reset "r" : 07 FF 4D 43 43 02 24 8D 72 00
Where xx = "0" to "2"
Where zz = Calculated Checksum
Available functions:
"0" = Normal (default)
"1" = Full Protection
"2" = Menu Protection
Auto Adjustment
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 8F xx zz
Function Examples:
Example "1" : 07 FF 4D 43 43 02 24 8F 31 3F
Query "?" : 07 FF 4D 43 43 02 24 8F 3F 31
Reset "R" : 07 FF 4D 43 43 02 24 8F 52 1E
Reset "r" : 07 FF 4D 43 43 02 24 8F 72 FE
Where xx = "0" to "1"
Where zz = Calculated Checksum
Available functions:
"0" = Off
"1" = On (default)
OSD Horizontal Position
Syntax : 07 FF 4D 43 43 03 23 90 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 90 35 30 0A
Query "?" : 07 FF 4D 43 43 02 24 90 3F 30
Reset "R" : 07 FF 4D 43 43 02 24 90 52 1D
Reset "r" : 07 FF 4D 43 43 02 24 90 72 FD
Increase "+" : 07 FF 4D 43 43 02 24 90 2B 44
Decrease "-" : 07 FF 4D 43 43 02 24 90 2D 42
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then
Value=100.
If Value is not multiple by ten, it
change to less nearest multiple
value.
OSD Vertical Position
Syntax : 07 FF 4D 43 43 03 23 91 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 91 35 30 09
Query "?" : 07 FF 4D 43 43 02 24 91 3F 2F
Reset "R" : 07 FF 4D 43 43 02 24 91 52 1C
Reset "r" : 07 FF 4D 43 43 02 24 91 72 FC
Increase "+" : 07 FF 4D 43 43 02 24 91 2B 43
Decrease "-" : 07 FF 4D 43 43 02 24 91 2D 41
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
Note: If Value > 100 then
Value=100.
If Value is not multiple by ten, it
change to less nearest multiple
value.
OSD Transparency
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 92 xx zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24 92 32 3B
Query "?" : 07 FF 4D 43 43 02 24 92 3F 2E
Reset "R" : 07 FF 4D 43 43 02 24 92 52 1B
Reset "r" : 07 FF 4D 43 43 02 24 92 72 FB
Increase "+" : 07 FF 4D 43 43 02 24 92 2B 42
Decrease "-" : 07 FF 4D 43 43 02 24 92 2D 40
Where xx = "0" to "7"
Where zz = Calculated Checksum
Default: "0"
Select OSD Menu Timeout
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23 93 xx yy zz
Function Examples:
Example "10" : 07 FF 4D 43 43 03 23 93 31 30 0B
Query "?" : 07 FF 4D 43 43 02 24 93 3F 2D
Reset "R" : 07 FF 4D 43 43 02 24 93 52 1A
Reset "r" : 07 FF 4D 43 43 02 24 93 72 FA
Increase "+" : 07 FF 4D 43 43 02 24 93 2B 41
Decrease "-" : 07 FF 4D 43 43 02 24 93 2D 3F
Where xx = "0" to "1"
Where yy = "0" to "E"
Where zz = Calculated Checksum
Max Range: "0" "0" to "1" "E"
Default: "0" "A"