Instruction Manual

28
Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command Syntax and Functionality Details and Values
PIP, PBP Contrast Control
Syntax : 07 FF 4D 43 43 03 23 A3 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 A3 35 30 F7
Query "?" : 07 FF 4D 43 43 02 24 A3 3F 1D
Reset "R" : 07 FF 4D 43 43 02 24 A3 52 0A
Reset "r" : 07 FF 4D 43 43 02 24 A3 72 EA
Increase "+" : 07 FF 4D 43 43 02 24 A3 2B 31
Decrease "-" : 07 FF 4D 43 43 02 24 A3 2D 2F
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "3" "2"
PIP Horizontal Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23 A4 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 A4 35 30 F6
Query "?" : 07 FF 4D 43 43 02 24 A4 3F 1C
Reset "R" : 07 FF 4D 43 43 02 24 A4 52 09
Reset "r" : 07 FF 4D 43 43 02 24 A4 72 E9
Increase "+" : 07 FF 4D 43 43 02 24 A4 2B 30
Decrease "-" : 07 FF 4D 43 43 02 24 A4 2D 2E
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
PIP Vertical Position
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 03 23 A5 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 A5 35 30 F5
Query "?" : 07 FF 4D 43 43 02 24 A5 3F 1B
Reset "R" : 07 FF 4D 43 43 02 24 A5 52 08
Reset "r" : 07 FF 4D 43 43 02 24 A5 72 E8
Increase "+" : 07 FF 4D 43 43 02 24 A5 2B 2F
Decrease "-" : 07 FF 4D 43 43 02 24 A5 2D 2D
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"
PIP Window Size Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 A6 xx zz
Function Examples:
Example "4" : 07 FF 4D 43 43 02 24 A6 34 25
Query "?" : 07 FF 4D 43 43 02 24 A6 3F 1A
Reset "R" : 07 FF 4D 43 43 02 24 A6 52 07
Reset "r" : 07 FF 4D 43 43 02 24 A6 72 E7
Increase "+" : 07 FF 4D 43 43 02 24 A6 2B 2E
Decrease "-" : 07 FF 4D 43 43 02 24 A6 2D 2C
Where xx = "1" to "7"
Where zz = Calculated Checksum
Default: "7"
Second Source Select
Note:
Not available on STD units.
Syntax : 07 FF 4D 43 43 02 24 A7 xx zz
Function Examples:
Example "4" : 07 FF 4D 43 43 02 24 A7 34 24
Query "?" : 07 FF 4D 43 43 02 24 A7 3F 19
Reset "R" : 07 FF 4D 43 43 02 24 A7 52 06
Reset "r" : 07 FF 4D 43 43 02 24 A7 72 E6
Where xx = "0" to "6"
Where zz = Calculated Checksum
Available functions:
"0" = Digital 1 (default)
"1" = Digital 2
"2" = Analog RGB1
"3" = Analog RGB2
"4" = Composite 1
"5" = Composite 2
"6" = Composite 3
Color Temperature Select
Syntax : 07 FF 4D 43 43 02 24 B3 xx zz
Function Examples:
Example "2" : 07 FF 4D 43 43 02 24 B3 32 1A
Query "?" : 07 FF 4D 43 43 02 24 B3 3F 0D
Reset "R" : 07 FF 4D 43 43 02 24 B3 52 FA
Reset "r" : 07 FF 4D 43 43 02 24 B3 72 DA
Where xx = "0" to "3"
Where zz = Calculated Checksum
Available functions:
"0" = 9300K
"1" = 8000K (default)
"2" = 6500K
"3" = USER
Examples on Response:
"8" "0" "0" "0" (8000k)
"U" "S" "E" "R" (USER)
Red Level for Selected Color
Temperature
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 03 23 B4 xx yy zz
Function Examples:
Example "50" : 07 FF 4D 43 43 03 23 B4 35 30 E6
Query "?" : 07 FF 4D 43 43 02 24 B4 3F 0C
Reset "R" : 07 FF 4D 43 43 02 24 B4 52 F9
Reset "r" : 07 FF 4D 43 43 02 24 B4 72 D9
Increase "+" : 07 FF 4D 43 43 02 24 B4 2B 20
Decrease "-" : 07 FF 4D 43 43 02 24 B4 2D 1E
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default MMD: "3" "2"