Serial/Ethernet Communication (SCOM) Interface
IND100084-14
MCC Command Syntax and Functionality Details and Values
Load User Default
Note:
Available function list differs
between MMD and STD units!
Syntax : 07 FF 4D 43 43 02 24 D8 xx zz
Function Examples:
Example "3" : 07 FF 4D 43 43 02 24 D8 33 F4
Where xx = "1" to "5"
Where zz = Calculated Checksum
Available functions (MMD):
"0" = Read Defaults
"1" = User1 Slot
"2" = User2 Slot
"3" = User3 Slot
"4" = User4 Slot
"5" = User5 Slot
Available functions (STD):
"0" = Read Defaults
"1" = User Slot
Available response status:
"0" = Fail
"1" = Successful
Swap Main & Second Source
Note:
Not available on STD units.
Send Only : 07 FF 4D 43 43 01 25 E3 1C
Available response status:
"0" = Fail
"1" = Successful
Gamma Reset
Note:
A power off/on to the unit is
required to reboot the internal
display code. This can either be
done by issue the "Power down
/ up" command described earlier
in this table or do a physical
power off/on for the unit.
Send Only : 07 FF 4D 43 43 01 25 E5 1A
Available response status:
"0" = Fail
"1" = Successful
Menu Button
Send Only : 07 FF 4D 43 43 01 25 F7 08
Physical Button press equivalent
Select-Down Button
Send Only : 07 FF 4D 43 43 01 25 FA 05
Physical Button press equivalent
Select-Up Button
Send Only : 07 FF 4D 43 43 01 25 FB 04
Physical Button press equivalent
Right / + Button
Send Only : 07 FF 4D 43 43 01 25 FC 03
Physical Button press equivalent
Left / - Button
Send Only : 07 FF 4D 43 43 01 25 FD 02
Physical Button press equivalent
See next page for "?", "R/r", "+" and "-" command descriptions.