User's Manual

USER MANUAL 12
Supports 1 group (#1, Lifeline) with up to 5 nodes. Command classes reported to the Lifeline:
1. NOTIFICATION_REPORT
2. BATTERY_REPORT
3. DEVICE_RESET_LOCALLY
4. INDICATOR_REPORT

Association Groups
Battery State and Charging
Battery state is checked upon startup and Battery CC V2 report is sent to the Lifeline Group.
Battery is then checked every 5 minutes. A battery report is also sent every 24 hours.
Indications and operation are as follows:
1. If battery falls below 25%, Battery report is sent to the Lifeline. One second later,


2. If battery falls below 10%, Battery report is sent to the Lifeline. One second later,


will no longer raise but can still be lowered.
3. When charger is plugged in, Battery report is sent to the Lifeline. One second later,


4. When charge is complete, Battery report is sent to the Lifeline. One second later,


Battery CC V2 support extended information in the Battery Report and can be queried at any
time with the Battery Get command. Additional information about the battery can be retrieved
with the Battery Health Get command.