User's Manual

15 HAVEN CONNECT Z
Glossary
NWI - Network Wide Inclusion
NWE - Network Wide Exclusion
S2 - Z-Wave Security Version 2
S0 - Z-Wave Security Version 1

Impact Detection
The impact detection function uses an accelerometer that is tuned using parameters 3 and 4 set


the Lifeline.
Parameter 4:
Name: Transient Threshold
Description: Impact detect parameter. Do not adjust unless advised by Haven Lock.
Default: 0x08
Min: 0x02
Max: 0x12
Parameter 3:
Name: Transient Debounce
Description: Impact detect parameter. Do not adjust unless advised by Haven Lock.
Default: 0x02
Min: 0x01
Max: 0x0A
Parameter 2:
Name: Gate Operation Minimum Battery Level%
Description: m battery level at which the gate will activate.
Default: 0x0A (10%)
Min: 0x00 (0%)
Max: 0x32 (50%)
Parameter 1:
Name: Heartbeat LED interval
Description: 
Default: 0x1E (30 seconds)
Min: 0x00 (disabled)
Max: 0x3C (60 seconds)
Conguration Parameters