11 HAVEN CONNECT Z
1. If the gate is raised manually, Notification Type Access Control, Event 0x01 (Manual lock
operation) is sent to the Lifeline then one second later, a Door Lock Operation Report is
sent to the Lifeline.
2. If the gate is lowered manually, Notification Type Access Control, Event 0x02 (Manual
unlock operation) is sent to the Lifeline and then one second later, a Door Lock Operation
Report is sent to the Lifeline.
Manual Lock Operation Reports
1. To Lock: Sending command class = COMMAND_CLASS_DOOR_LOCK, command =
DOOR_LOCK_OPERATION_SET, mode = 0xFF (DOOR_SECURED) or BASIC_SET value
0xFF will raise the gate. Notification Type Access Control, Event 0x03 (RF lock operation)
is sent to the Lifeline and then one second later, a Door Lock Operation Report is sent to
the Lifeline.
2. To Unlock: Sending command class = COMMAND_CLASS_DOOR_LOCK, command =
DOOR_LOCK_OPERATION_SET, mode = 0x00 (DOOR_UNSECURED) or BASIC_SET
value 0x00 will lower the gate. Notification Type Access Control, Event 0x04 (RF unlock
operation) is sent to the Lifeline and then one second later, a Door Lock Operation Report
is sent to the Lifeline.
Z-Wave Lock Operation
SmartStart-enabled products can be added into a Z-Wave network by scanning the Z-wave
QR Code present on the product with a controller providing SmartStart inclusion. No
further action is required and the StartStart product will be added automatically within 10
minutes of being switched on in the network vicinity.
Locate the DSK via the QR code label under the Haven electronics hood adjacent to the
buttons and LEDs.