Installation Guide

8 3/4"
222mm
FROM HANGER
BRACKET HOLES
PAGE 19 OF 21
RETROFIT INSTALLATION
DETAILS
NOTES:
THE 12XX COOLER SERIES IS ABLE TO RETROFIT IN PLACE OF A NUMBER OF COMPETITOR MODELS. SEE
RETROFIT TABLE ABOVE FOR PARTIAL LIST OF COOLERS ABLE TO BE REPLACED BY THIS ONE.
THE FOLLOWING DISCLAIMERS APPLY:
THE 12XX COOLER CENTERLINE MAY NOT MATCH THE OLD COOLER'S CENTERLINE, SINCE THE 12XX
COOLER DRAIN MUST BE 2 5/8" OFF OF CENTER. THIS MAY AFFECT ADA COMPLIANCE.
FOR HI-LO COOLER RETROFITS, EXISTING RIGHT-SIDE COOLER MUST BE THE LOW COOLER. DRAIN,
WATER, AND ELECTRIC SERVICES MUST BE POSITIONED BEHIND RIGHT-SIDE UNIT.
THERE MUST BE WALL BLOCKING OR OTHER STRUCTURAL MATERIAL BEHIND HAWS MOUNTING HOLES.
VERIFY THAT DRAIN, ELECTRIC, & WATER SERVICES ARE LOCATED WITHIN BOUNDARIES SPECIFIED ON
THIS SHEET AND THE NEXT. SOME RETROFITS MAY REQUIRE THE ELECTRIC OUTLET TO BE MOVED.
THE P-TRAP IS NOT SUPPLIED. THE VERTICAL DIMENSIONS GIVEN ARE BASED UPON INSTALLATION USING
OF A KEENEY 200W P-TRAP, AND SHOULD THEREFORE BE REGARDED AS REFERENCE-ONLY.
THE CENTERLINE OF THE DRAIN STUB-OUT MUST BE BETWEEN 3" [76mm] & 4-5/8" [118mm] OR BETWEEN 6"
[152mm] & 8-3/4" [229mm] BELOW THE LOWERMOST EWC MOUNTING BRACKET HOLES IN ORDER FOR THE
P-TRAP TO AFFIX PROPERLY TO THE DRAIN TAILPIECE.
- DEPENDING ON STUB-OUT HEIGHT, SOME TRIMMING OF THE TAILPIECE WILL BE REQUIRED.
- MOUNTING THE STUB-OUT IN THE HIGHER RANGE WILL REQUIRE TRIMMING THE TAILPIECE ABOVE THE
LOWER DRAIN HOSE BRANCH. IN THIS INSTANCE, THEREFORE, A HI-LO COOLER CANNOT BE
INSTALLED.
WHATEVER P-TRAP AND STUB-OUT PLUMBING ARE USED, CARE SHOULD BE TAKEN TO ENSURE THAT THE
P-TRAP CAN SEAL TO THE STUB-OUT PROPERLY AND STILL ALIGN TO THE DRAIN TAILPIECE (LOCATED AT
THE GIVEN DIMENSIONS).
3
4
5
6
HIGHEST & LOWEST
P-TRAP HEIGHTS
5
LOW COOLER BRACKET HEIGHT
ADULT STANDING ADULT ADA CHILD ADA
33 7/8" 28 3/8" 25 3/8"
RETROFIT TABLE
MANUFACTURER MODEL
HAWS
ALL MODELS STARTING WITH
HWUACP
ELKAY/HALSEY
TAYLOR
- ALL MODELS STARTING WITH EB,
EI, EMA, EN, EZ, HAC HVR, LI, LMA,
LZ, TB, & TI
- SINGLE COOLER MODELS
STARTING WITH VRC & LVR
OASIS ALL VERSACOOLER II MODELS
SUNROC ALL MODELS STARTING WITH ADA
MURDOCK
A171, A171.8, & A172.8UBL MODELS
NOTE: THE WATER STOP VALVE
MUST BE RELOCATED TO RETROFIT
A FILTERED 12XX COOLER
3
PAGE 19 OF 21
DRAIN STUB-OUT/P-TRAP DETAIL
(VIEWED FROM TOP)
DRAIN
STUB-OUT
(NOT SUPPLIED)
1-1/4" P-TRAP
(NOT SUPPLIED)
WALL
FACE
6
2 7/8"
73mm
6 5/16"
161mm
2 3/8"
61mm
MAX
CAN'T USE WITH
HI-LO MODELS.
3" [76mm]
FROM HANGER
BRACKET HOLES
© 2020 Haws Corporation - All Rights Reserved. HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.
SHEET 5 OF 7
5
FLOOR LINE
MOUNTING BRACKET
HAWS COOLER
NOTE LOCATING
NOTCH FOR
DRAIN STUB-OUT
CENTERLINE
PERMISSIBLE LOCATIONS FOR DRAIN STUB-OUT
3"
76mm
4 5/8"
117mm
6"
152mm
8 3/4"
222mm
BRACKET
HEIGHT
(SEE TABLE
ABOVE)
2 5/8"±1/4"
67mm±6